Energy Storage System

An energy storage system (ESS or BESS) is a battery bank with an inverter, packaged for mobile or temporary deployment, that stores electrical energy and delivers it as AC power on demand. On job sites these units run silent overnight loads, shave generator runtime in hybrid setups, and provide clean power where noise or emissions rules constrain engines.

16
Modelos
24–1,303 kVA across cataloged models
Power output
6
Marcas
Energy Storage System

Cómo funciona

The battery bank — most commonly lithium-based in current mobile units — feeds a power-electronic inverter that produces stable AC output at the required voltage and frequency. A battery management system supervises cell voltages, temperature, and state of charge, protecting the pack from over-charge and over-discharge. In hybrid configurations the ESS pairs with a generator: the battery carries light and overnight loads, and the system starts the engine only when load rises or the pack needs recharging. This cuts fuel burn, noise, and engine hours compared to running a diesel set continuously at low load.

Tipos y variantes

Portable battery energy storage units
Compact wheeled or skid units delivering AC power for tools, lighting, and trailers without engine noise or exhaust.
Trailer-mounted BESS
Larger towable systems that substitute for mid-size generators on noise- or emissions-restricted sites.
Hybrid generator-storage systems
Storage paired with a diesel set under shared controls, running the engine only when needed.
UPS-class systems
Storage engineered for uninterrupted transfer, protecting critical loads such as IT and life-safety equipment during outages.

Especificaciones clave

EspecificaciónRango típicoQué significa
Power output24–1,303 kVA across cataloged modelsThe inverter's rating caps how much load the unit can serve at once; like generators, kW output equals kVA times power factor.
Energy capacityRated in kWh, model dependentCapacity sets how long the unit sustains a given load before recharging; runtime equals usable kWh divided by average load in kW.
Recharge sourceGrid connection, generator, or solar input depending on configurationDetermines how the system fits into a site power plan and how quickly it returns to full charge.
Output configurationSingle- and three-phase AC at standard site voltages, model dependentMust match the distribution equipment and loads the unit will serve.

Cómo la industria lo dimensiona

Storage systems are sized on two axes: power (kW/kVA, the instantaneous load the inverter can carry) and energy (kWh, how long that load can be sustained). A unit is selected by matching inverter rating to peak connected load and battery capacity to the load profile between recharge opportunities. In hybrid duty the storage is typically sized to carry the site's overnight and idle loads so the generator can shut down entirely for those hours.

Aplicaciones

  • Silent overnight power for site offices, security systems, and lighting
  • Hybrid pairing with diesel generators to cut fuel use and engine hours
  • Temporary power on emissions- or noise-restricted urban sites
  • Backup power for critical loads during planned outages
  • Powering electric tools and equipment charging where grid service is absent

Seguridad y operación

  • Lithium battery systems carry thermal-runaway risk; follow manufacturer clearances and never operate a unit with visible pack damage.
  • Treat the AC output like any generator output: distribution must be grounded, bonded, and GFCI-protected per the NEC.
  • Charge and stage units per NFPA 855 separation guidance where systems are grouped or stored indoors.
  • Only qualified personnel should service the DC side; pack voltages remain lethal with the inverter off.

Normas y certificaciones

UL · UL 9540 / UL 9540A
Safety standard for energy storage systems and the test method for thermal-runaway fire propagation.
NFPA · NFPA 855
Installation standard for stationary energy storage systems, including separation and capacity limits.
UL · UL 1973
Safety standard for the battery packs used in stationary and motive ESS applications.
NFPA · NFPA 70 (NEC), Article 706
Code requirements for energy storage system installations.

Preguntas frecuentes

How is a battery energy storage system different from a generator?
A generator converts fuel to power continuously; an ESS delivers stored energy silently with no emissions at the point of use, but must be recharged. Power rating governs both, while runtime on an ESS is fixed by battery capacity rather than tank size.
What does a hybrid generator-storage setup accomplish?
The battery carries light loads and overnight demand, so the diesel engine runs only at efficient load levels and shuts off otherwise. The result is lower fuel burn, fewer engine hours, and quiet nights, with the generator recharging the pack while it runs.
How is runtime estimated for a storage unit?
Divide usable battery capacity in kWh by the average load in kW. A load profile with high peaks but a low average runs far longer than the peak figure alone suggests, which is why load profiling matters more for storage than for generators.

Comparar modelos populares

Buscar por especificación →

Normalizado a las mismas unidades. Un guion significa que el valor no fue publicado.

ModeloPotencia de salidaCapacidad de combustible
Atlas Copco ZBP 2000 --
JCB 19C-1E --

Equipos relacionados

Explorar por fabricante

Fuentes

Cada especificación se verifica con los datos publicados por el fabricante, con la fuente enlazada como referencia.

Todos los modelos

16 modelos · Cada especificación citada a la fuente

Dewalt DCB1800B
Dewalt · Power Stations
Liebert Vertiv Liebert PSI5 UPS, 750VA-5000VA
Liebert · Uninterruptible Power Supply
Liebert Vertiv Liebert GXT5 UPS, 3000-20000VA, 208VAC
Liebert · Uninterruptible Power Supply
85.0 kVA
Liebert Vertiv Liebert GXT5 UPS, 500VA-3000VA, 120V
Liebert · Uninterruptible Power Supply
Atlas Copco ZBP 2000
Atlas Copco · Energy Storage System
Liebert Vertiv Liebert EXL S1 UPS, 250-1200kW
Liebert · Uninterruptible Power Supply
1,303.0 kVA
Liebert Vertiv Liebert EXM UPS, 10-250kVA
Liebert · Uninterruptible Power Supply
JCB 19C-1E
JCB · Charging Solutions
Liebert Vertiv Liebert ITA2 UPS, 15-40kVA, 400V Three-Phase
Liebert · Uninterruptible Power Supply
Liebert Vertiv Liebert ITA2 UPS, 5-40kVA, 208V Three-Phase
Liebert · Uninterruptible Power Supply
Liebert Vertiv PowerDirect 3000 33kW, OCP ORV3 HPR- 50 VDC Power System
Liebert · DC Power System
41.2 kVA
Liebert Vertiv Liebert APM Modular UPS, 15-90kVA
Liebert · Uninterruptible Power Supply
30.0 kVA
Craftsman CMCB1150B
Craftsman · Portable Power Station/inverter
150.0 kVA
Generac MBE30
Generac · Mobile Energy Storage
24.0 kVA
Generac MBE40
Generac · Mobile Energy Storage
32.0 kVA
Liebert Vertiv Liebert NX UPS, 40-200kVA Three-Phase
Liebert · Uninterruptible Power Supply