Ramfan
36 models - manufacturer-sourced specifications, datasheets and manuals.
| Model | Type | Key specs | Documents |
|---|---|---|---|
| GX355ES | Aircraft Brake Cooling Fan | Dimensions (H x W x D) 21.2 x 22.4 x 19.8 in / 54 x 57 x 50 cm; Engine Honda GX200 5.5 Hp / 4.1 kW; Impeller 7-Blade | |
| EX150Li (52V) | Battery PPV Fan | AC Power Consumption 1638 W; Airflow (Battery, AMCA Verified) 21,041 m³/hr; Battery Energy 749 Wh (per pack) | Manual |
| EX50Li Gen II (40V) | Battery PPV Fan | AC Power Consumption 700 W; Airflow (AMCA Verified) 17,204 m³/hr; Battery Energy 432 Wh (6Ah) / 720 Wh (10Ah) Wh | Manual |
| EX50Li-18V | Battery PPV Fan | Airflow (AMCA Verified) 17,585 m³/hr; Battery Compatibility Milwaukee M18 / DeWalt 20V; Dimensions (H x W x D) 22 x 21 x 16 in / 56 x 53 x 41 cm | Manual |
| EFi50/EFi120/EFi150 | Electric Confined Space Blower | Airflow (15ft duct, 1 turn) 1,934 cfm; Airflow Free Air (EFi50) 3,200 cfm; Amps (Start/Run, EFi50, 115V) 25A / 6A A | Manual |
| UB20 | Electric Confined Space Blower | Airflow (15ft duct, 1 turn, 115V) 789 cfm; Airflow (Free Air, 115V) 1,666 m³/hr; Amps (Start/Run) 9.5A / 2.5A A | Manual |
| UB30 | Electric Confined Space Blower | Airflow (15ft duct, 1 turn, 115V) 2,050 cfm; Airflow (Free Air, 115V) 4,114 m³/hr; Amps (Start/Run) 33A / 8A (115V) A | Manual |
| XP400/XP420 | Electric Explosion-Proof PPV Fan | Airflow 11,391 cfm; Amps (Start/Run) 80A / 15A A; Certification UL/IECEx/ATEX explosion-proof motor | Manual |
| XP500/XP520 | Electric Explosion-Proof PPV Fan | Airflow (115V) 10,589 cfm; Airflow (230V) 8,824 cfm; Amps (Start/Run) 80A / 15A A | Manual |
| EFi120xx/EFi150xx | Electric Hazardous Location Blower | Airflow (15ft duct, 1 turn, EFi120xx) 2,700 cfm; Airflow (15ft duct, 1 turn, EFi150xx) 3,179 cfm; Airflow Free Air (EFi120xx) 3,750 cfm | Manual |
| EFi50xx | Electric Hazardous Location Blower | Airflow (15ft duct, 1 turn) 1,935 cfm; Airflow (Free Air) 3,200 cfm; Amps (Start/Run, 115V) 13A / 3A A | Manual |
| EFi75xx | Electric Hazardous Location Blower | Airflow (15ft duct, 1 turn) 1,664 cfm; Airflow (Free Air) 2,500 cfm; Amps (Start/Run, 115V) 27A / 4.4A A | Manual |
| UB20xx | Electric Hazardous Location Blower | Airflow (15ft duct, 1 turn, 115V) 789 cfm; Airflow (Free Air, 115V) 980 cfm; Airflow (Free Air, 230V) 819 cfm | Manual |
| EFC50x/EFC120x/EFC150x | Electric Hazardous Location Smoke Ejector | Airflow Free Air (EFC120x) 3,750 cfm; Airflow Free Air (EFC150x) 4,459 cfm; Airflow Free Air (EFC50x) 3,200 cfm | Manual |
| EV400/EV420 | Electric PPV Fan | Airflow (115V) 19,365 m³/hr; Airflow (230VAC) 10,994 cfm; Amps (Run) 15A or 20A A | Manual |
| EX400/EX420 | Electric PPV Fan | Airflow (115V) 11,391 cfm; Airflow (230V) 10,994 cfm; Amps (Run) 15A or 20A A | Manual |
| EX500/EX520 | Electric PPV Fan | Airflow (115V) 19,618 m³/hr; Airflow (230V) 13,354 cfm; Amps (Run) 15A or 20A A | Manual |
| EFC50/EFC120/EFC150 | Electric Smoke Ejector | Airflow Free Air (EFC120) 3,750 cfm; Airflow Free Air (EFC150) 4,459 cfm; Airflow Free Air (EFC50) 3,200 cfm | Manual |
| G3 | Fire Rescue Fan | ||
| VX700 | Gas Large Structure Ventilator | Airflow (Double Door) 79,390 m³/hr; Airflow (Warehouse Door) 60,200 cfm; Dimensions (H x W x D) 49 x 33.3 x 47.3 in | Manual |
| GF164GP | Gas PPV Fan | Airflow (TurboForce) 19,810 m³/hr; Dimensions (H x W x D) 53 x 51 x 43 cm; Engine Honda GP160, 163 cm³, 3.6 kW | Manual |
| GF164SE | Gas PPV Fan | Airflow (Single Door, TurboForce) 17,099 m³/hr; Dimensions (H x W x D) 21 x 20 x 17 in / 53 x 51 x 43 cm; Engine Honda GC160 4.6 Hp / 3.4 kW | Manual |
| GF165 | Gas PPV Fan | Airflow (Single Door, TurboForce) 21,940 m³/hr; Dimensions (H x W x D) 22 x 20.2 x 20 in / 56 x 51 x 51 cm; Engine Honda GX160 4.8 Hp / 3.5 kW | Manual |
| GF210 | Gas PPV Fan | Airflow (Double Door) 22,500 cfm; Airflow (Single Door) 17,670 cfm; Dimensions (H x W x D) 24.8 x 25.3 x 22.4 in / 63 x 64.3 x 22.4 cm | Manual |
| GX200 | Gas PPV Fan | Airflow (Single Door) 21,760 m³/hr; Dimensions (H x W x D) 21.5 x 19.5 x 20.5 in / 55 x 50 x 52 cm; Engine Honda GXH50 2.1 Hp / 1.6 kW | Manual |
| GX310 | Gas PPV Fan | Airflow (Single Door) 28,846 m³/hr; Dimensions (H x W x D) 55 x 55 x 50 cm; Engine Honda GX160 4.8 Hp / 3.5 kW | Manual |
| GX350 | Gas PPV Fan | Airflow (Single Door) 31,799 m³/hr; Dimensions (H x W x D) 21.2 x 22.4 x 19.8 in / 54 x 57 x 50 cm; Engine Honda GX200 5.5 Hp / 4.1 kW | Manual |
| GX400 | Gas PPV Fan | Airflow (Double Door) 22,500 cfm; Airflow (Single Door) 16,797 cfm; Dimensions (H x W x D) 24.9 x 25 x 22 in / 63 x 64 x 56 cm | Manual |
| GX500 | Gas PPV Fan | Airflow (Double Door) 47,260 m³/hr; Airflow (Warehouse Door) 37,700 cfm; Dimensions (H x W x D) 30.06 x 29.13 x 24.67 in / 76.3 x 73.9 x 62.6 cm | Manual |
| GX600 | Gas PPV Fan | Airflow (Double Door) 55,250 m³/hr; Airflow (Warehouse Door) 49,000 cfm; Dimensions (H x W x D) 34.5 x 37.3 x 30.3 in / 88 x 95 x 77 cm | Manual |
| AFi50xx | Pneumatic Hazardous Location Blower | Air Consumption 40 scfm scfm; Airflow (Free Air, 80 psi) 5,440 m³/hr; Compressor Required 6.4 Hp hp | Manual |
| AFi75xx | Pneumatic Hazardous Location Blower | Airflow (Free Air, 80 psi) 3,471 m³/hr; Compressor Required 6.4 Hp hp; Dimensions (H x W x D) 16 x 17 x 16 in / 41 x 43 x 41 cm | Manual |
| WF20 | Water-Powered PPV Fan | Airflow (Ducted, 150 psi) 1,835 cfm; Airflow (PPV with Multiplier, 150 psi) 13,125 cfm; Airflow (PPV with Multiplier, 250 psi) 16,511 cfm | Manual |
| WF390L | Water-Powered PPV Fan | Airflow (PPV Single Door) 29,610 m³/hr; Impeller 7-Blade; Tilt Adjustment 0° to 20° | Manual |
| WF540 | Water-Powered PPV Fan | Airflow (Open, 1.0 MPa) 57,231 m³/hr; Airflow (PPV, AMCA, 1.0 MPa) 38,154 m³/hr; Dimensions (H x W x D) 65 x 63 x 53 cm | Manual |
| WX500 | Water-Powered PPV Fan | Airflow (PPV, 150 psi) 27,464 m³/hr; Dimensions (H x W x D) 23.8 x 21 x 19.1 in / 61 x 54 x 49 cm; Fan Diameter 18 in |