Cooling Tower

A cooling tower rejects heat from condenser or process water to the atmosphere by evaporation: warm water spreads over fill media while a fan draws air through it, cooling the water for return to chillers or process loops. The catalog lists 78 models from brands including Marley, Evapco, Baltimore Aircoil Company, Thermal Care, Delta Cooling Towers, Tower Tech, and Recold.

77
Modèles
Sized by ton
Nominal capacity
6
Marques
Cooling Tower

Fonctionnement

Warm water from the condenser loop distributes over fill — thin sheets or splash surfaces that maximize air-water contact. A fan moves air through the fill, evaporating a small fraction of the water and carrying the heat away; the cooled water collects in a basin and pumps back to the load. Drift eliminators capture entrained droplets, and makeup water replaces evaporation and blowdown. Closed-circuit variants keep process fluid inside a coil, spraying water over the coil so the loop stays clean while heat still leaves by evaporation.

Types et variantes

Open-circuit induced-draft towers
The standard configuration — a top fan pulls air through fill in direct water contact.
Forced-draft towers
Fans push air into the tower; common in compact and indoor-ducted designs.
Closed-circuit fluid coolers
Coil-isolated loops for clean process fluid with evaporative performance.
Portable and temporary towers
Skid- or trailer-mounted towers for outages, shutdowns, and project loads.
Crossflow and counterflow designs
Air path geometries trading height, footprint, and maintenance access.

Spécifications clés

SpécificationPlage typiqueSignification
Nominal capacitySized by tonHeat rejection rating matched to the chiller or process load.
Design water flowVaries by model and capacityThe gpm the tower is rated to cool through its design temperature range.
Fan powerVaries by model and capacityDrives airflow and thus thermal performance and sound level.
Approach temperatureVaries by selection and site conditionsHow close the leaving water gets to ambient wet-bulb — the core performance measure.

Comment l'industrie le dimensionne

Cooling towers are sized by heat rejection in nominal tons at design wet-bulb, flow, and range. Selection matches the chiller or process load at the site's design wet-bulb temperature, then checks footprint, water treatment, and electrical supply. Units from 0 to 200 tons reject heat from a single water-cooled chiller or one process loop; 200 to 500 ton units serve as standard temporary towers for a building's chilled water plant during an outage; 500 to 1,000 ton towers handle large plant and process cooling — usually two or more chillers on one tower; units above 1,000 tons provide plant-scale heat rejection for refinery, power, and data-centre turnarounds.

Applications

  • Condenser water cooling for chiller plants
  • Process cooling for manufacturing and industrial loads
  • Temporary heat rejection during shutdowns and tower replacements
  • Data center and campus central plant support
  • Supplemental capacity for peak-season loads

Sécurité et opération

  • Cooling towers can harbor Legionella; ASHRAE 188 water management programs — treatment, monitoring, cleaning — are the controlling practice.
  • Fan and pump lockout precedes any basin, fill, or mechanical work.
  • Tower access involves work at height; ladders, platforms, and fall protection follow OSHA requirements.
  • Chemical water treatment is handled per its hazard documentation, away from drift and intake paths.

Normes et certifications

CTI · STD-201
Thermal performance certification for evaporative heat rejection equipment.
ASHRAE · 188
Legionellosis risk management for building water systems, including cooling towers.
NFPA · 214
Fire protection standard for water-cooling towers.

Questions fréquentes

How much water does a tower consume?
Evaporation carries away roughly the heat load's equivalent in water, plus blowdown to control dissolved solids. Makeup water supply and treatment are part of every installation plan.
Open or closed circuit — how is the choice made?
Open towers are simpler and cheaper per ton; closed-circuit fluid coolers keep the process loop sealed and clean at some performance and cost premium — decisive where loop fouling is unacceptable.
What is approach and why does it matter?
The gap between leaving water temperature and ambient wet-bulb. Tight approaches need more fill and fan — a tower cannot cool below wet-bulb, so local climate bounds the achievable water temperature.

Parcourir par fabricant

Sources

Chaque spécification est vérifiée par rapport aux données publiées par le fabricant, avec la source liée pour référence.

Tous les modèles

77 modèles · Page 2 sur 2 · Chaque spécification citée à la source

Baltimore Aircoil Company Series V Closed Circuit Cooling Tower
Baltimore Aircoil Company · Closed Circuit Cooling Tower
Baltimore Aircoil Company Series V Cooling Tower
Baltimore Aircoil Company · Cooling Tower
Evapco AT Cooling Tower
Evapco · Cooling Tower
Evapco EAW-FD Flat Dry Cooler
Evapco · Air-Cooled Closed Circuit Cooler
Evapco EAW-HD APEX Dry Cooler
Evapco · Air-Cooled Closed Circuit Cooler
Evapco EAW-VA V Adiabatic Cooler
Evapco · Air-Cooled Closed Circuit Cooler
Evapco LSWE Closed Circuit Cooler
Evapco · Closed Circuit Cooler
Marley NCWD
Marley · Crossflow Hybrid Wet/Dry Cooling Tower
Baltimore Aircoil Company FXT Cooling Tower
Baltimore Aircoil Company · Cooling Tower
Baltimore Aircoil Company FXV Closed Circuit Cooling Tower
Baltimore Aircoil Company · Closed Circuit Cooling Tower
Baltimore Aircoil Company FXV3 Closed Circuit Cooling Tower
Baltimore Aircoil Company · Closed Circuit Cooling Tower
Baltimore Aircoil Company PFi Closed Circuit Cooling Tower
Baltimore Aircoil Company · Closed Circuit Cooling Tower
Baltimore Aircoil Company PT2 Cooling Tower
Baltimore Aircoil Company · Cooling Tower
Baltimore Aircoil Company Series 1500 Cooling Tower
Baltimore Aircoil Company · Cooling Tower
Baltimore Aircoil Company Series 3000 Cooling Tower
Baltimore Aircoil Company · Cooling Tower
Evapco eco-ATWB Closed Circuit Cooler
Evapco · Closed Circuit Cooler
Marley 600 Field Erected
Marley · Crossflow Field-Erected Cooling Tower
Baltimore Aircoil Company Series 5000 Industrial Grade Modular Cooling Tower
Baltimore Aircoil Company · Cooling Tower
Baltimore Aircoil Company TrilliumSeries Dry Cooler
Baltimore Aircoil Company · Dry Cooler
Marley 800 Natural Draft
Marley · Natural Draft Field-Erected Cooling Tower
Evapco eco-LRWB Closed Circuit Cooler
Evapco · Closed Circuit Cooler
Marley 400/800MD Unilite
Marley · Counterflow Field-Erected Cooling Tower
Marley ClearSky Plume Abatement
Marley · Plume Abatement Cooling Tower
Marley MS / Architectural
Marley · Architectural Field-Erected Cooling Tower
Marley PPWD Hybrid Plume Abatement
Marley · Hybrid Plume Abatement Cooling Tower
Marley Round Forced Draft
Marley · Round Forced Draft Cooling Tower
Marley Round Hybrid Plume Abatement
Marley · Natural Draft Plume Abatement Cooling Tower
Baltimore Aircoil Company Nexus Modular Hybrid Cooler
Baltimore Aircoil Company · Hybrid Cooler
Evapco AT 110-2I12
Evapco · Advanced Technology Cooling Tower
← Préc. Page 2 sur 2