12 models - manufacturer-sourced specifications, datasheets and manuals.

Model Type Key specs Documents
Box Style Aerator Box Aerator Flow Rate Range 100–3,000 GPM; Shell Materials Available Aluminum, Stainless Steel, Fiberglass; Typical Applications pH adjustment (CO2 removal), H2S removal, pre-oxidize Iron and Manganese
Vanguard Air Stripper / Degassifier Forced Draft Air Stripper Assembly Modular, pre-assembled; Contaminants Removed TCE, PCE, 1,1-DCA, vinyl chloride, carbon tetrachloride, BTEX, MTBE, H2S, CO2, ammonia, VOCs; Design Type Forced draft, countercurrent air stripping
Pioneer Forced Draft Cooling Tower Cooling Capacity Range 10–100 tons; Draft Type Forced draft, counterflow; Fan Type Forward curved centrifugal blower
Paragon Induced Draft Cooling Tower Cooling Capacity Range 55–250 tons; Drift Eliminator Polyethylene; Fan Type Direct drive, fiberglass-reinforced polypropylene propeller
TM Series Induced Draft Cooling Tower Cooling Capacity (1 Cell) 250–425 tons; Cooling Capacity (6 Cells) 1,340–2,400 tons; Cooling Capacity Range 250–2,500 tons
TMX Series Induced Draft Cooling Tower Cooling Capacity (1 Cell) 309–600 tons; Cooling Capacity (6 Cells) 1,943–3,251 tons; Dimensions (1 Cell, L x W x H) 20.5' x 8.5' x 17.6'
Anti-Microbial Cooling Tower Induced Draft Cooling Tower (Anti-Microbial) Anti-Microbial Efficacy (Shell) Yes — confirmed by Special Pathogens Laboratory testing (Legionella Pneumophila Serogroup 1); Anti-Microbial Efficacy vs FRP FRP Shell: No efficacy; Anti-Microbial Efficacy vs Stainless Steel Stainless Steel Shell: No efficacy
Delta-Pak PVC Structured Tower Packing Media Configuration Series of long, parallel tubes; Design Spirally wound structured packing; Material PVC
ES Delta Evaporative System Packaged Cooling System Corrosion Resistance Rust and corrosion proof; Included Components Pump(s), control panel, pre-wired and pre-piped skid components; Optional Addition Plate and frame heat exchanger for closed-loop process side
DS Delta Dry System Packaged Cooling System (Closed Loop, Plate Heat Exchanger) Energy Standard ASHRAE 90.1 compliant; Expandability Heat exchanger capacity can be increased by adding plates; Heat Exchanger Plates Stainless steel
PTS Delta Pump Tank System Packaged Cooling System (Pump Tank Skid) Included Components Cooling tower pumps, storage tank, control panel, pre-piped and pre-wired on common skid; Installation Time 1 day; Shell Design One-piece, no seams, welds, or patches
Vanguard Scrubber / Odor Control Wet Air Scrubber Air Flow Rate Range 1,000–75,000 CFM per column; Target Contaminants H2S (hydrogen sulfide), ammonia; Technology Wet scrubbing