Aller au contenu
Catalogue

Marley

32 models - manufacturer-sourced specifications, datasheets and manuals.

Model Type Key specs Documents
Marley MS / Architectural Architectural Field-Erected Cooling Tower Configuration Field erected, custom architectural enclosures; Flow Rate 240–30,000 gpm; Notable Installation Depth Up to 30 feet underground
Marley CP Counterflow Cooling Tower Assembly Options Factory-assembled, preassembled modules, or knock-down; Casing Fiberglass reinforced polyester (FRP); Certifications CTI Certified, Eurovent, Eurocode 3
Marley CR Counterflow Cooling Tower Certifications CTI Certified; Configuration Induced-draft, counterflow; Drift Rate Below 0.001%
Marley MD Counterflow Cooling Tower Bearing L10 Life 100,000 hours; Certifications CTI Certified, FM Approved, ASHRAE 90.1, Eurovent, OSHA; Configuration Factory-assembled, counterflow, induced-draft
Marley MD Everest Counterflow Cooling Tower Capacity vs. Competitors Up to 58% more; Certifications CTI Certified, Eurovent, FM Approved, OSHA; Configuration Counterflow, induced draft, factory assembled Datasheet Manual
Marley 400/800MD Unilite Counterflow Field-Erected Cooling Tower Configuration Counterflow, mechanical draft; Flow Rate 700–30,000 gpm; Structure Material Options Fiberglass pultrusion, concrete, or wood
Marley AQUATOWER Crossflow Cooling Tower Certifications CTI Certified, ASHRAE 90.1, OSHA; Configuration Factory assembled, crossflow; Fill Type PVC film-fill
Marley AV Crossflow Cooling Tower Access Door Size 23 × 52 inches; Bearing L10 Life 50,000–100,000 hours; Certifications CTI Certified, ASHRAE 90.1, OSHA
Marley NC Crossflow Cooling Tower Certifications CTI Certified, FM Approved, ASHRAE 90.1, Eurovent, OSHA; Configuration Crossflow, factory assembled or field-erected; Drift Rate 0.0005 % of circulating water flow Datasheet Manual
Marley NC Alpha (Splash Fill) Crossflow Cooling Tower Application Dirty water cooling systems; Certifications OSHA compliant; Configuration Crossflow, factory assembled, splash fill
Marley NC Everest Crossflow Cooling Tower Capacity vs. Other Factory-Assembled Towers Up to 50% greater; Certifications CTI Certified, FM Approved, ASHRAE 90.1, Eurovent, OSHA; Configuration Crossflow, factory assembled Datasheet
Marley NC Fiberglass Crossflow Cooling Tower Certifications CTI Certified, Eurovent, ASHRAE 90.1; Configuration Crossflow, factory assembled or field erected; Drift Rate 0.0005 % of design flow
Marley NX Crossflow Cooling Tower Basin/Panels Fiberglass reinforced plastic (FRP); Certifications CTI Certified; Configuration Crossflow, field-assembled
Marley 600 Field Erected Crossflow Field-Erected Cooling Tower Application Ideal for poor water quality; Configuration Double-flow, vertical discharge crossflow, field erected; Fill Type Options Splash-fill PVC, polypropylene, or wood
Marley Series 10 and Series 15 Crossflow Field-Erected Cooling Tower Certifications OSHA compliant; Configuration Field-constructed, splash fill, crossflow; Drift Eliminators XCEL® PVC (or herringbone wood)
Marley Sigma Crossflow Field-Erected Cooling Tower Certifications ASHRAE 90.1, OSHA; Configuration Crossflow, field-erected; Fan Drive Right-angle Geareducer
Marley NCWD Crossflow Hybrid Wet/Dry Cooling Tower Flow Rate 1,180–3,100 gpm; Operating Weight vs. Comparable Up to 40% less; Plume Reduction One-third to one-fifth visible plume vs. series path designs
Marley DTC Evaporative Condenser Evaporative Condenser Certifications OSHA Compliant; Configuration Induced draft counterflow; Drive System Marley Geareducer® (5-year warranty) or belt drive
Recold JC Evaporative Condenser Evaporative Condenser Availability North America; Certifications OSHA compliant; Coil Material Copper, 5/8" O.D. tubes; stainless steel tube sheets; copper headers
Recold LC Evaporative Condenser Evaporative Condenser Access Doors per Cell 6–10 (gasketless, tool-free); Availability North America; Certifications ASHRAE 90.1, OSHA
Recold MC Evaporative Condenser Evaporative Condenser Availability North America; Certifications OSHA, EPACT; Coil Material Copper, 5/8" O.D. tubes; stainless steel tube sheets; copper headers
SGS DTC Industrial Evaporative Condenser Evaporative Condenser Availability North America; Certifications OSHA compliant; Configuration Induced Draft Counterflow
SGS IEC Industrial Evaporative Condenser Evaporative Condenser Availability North America; Casing Treatment Hot-dip galvanized (HDG); Certifications OSHA Compliant
Marley DT Fluid Cooler Evaporative Fluid Cooler Certifications CTI Certified, ASHRAE 90.1, OSHA; Configuration Induced-Draft, Closed-Circuit, Counterflow, Coil-Only; Drive System Marley Geareducer (5-year warranty)
Marley LW Fluid Cooler Evaporative Fluid Cooler Access Doors per Cell 6–10 (gasketless, tool-free removable); Certifications CTI Certified, ASHRAE 90.1, OSHA; Coil Material Copper (30–40% lighter than galvanized steel alternatives)
Marley MH Element Fluid Cooler Evaporative Fluid Cooler Certifications CTI Certified, ASHRAE 90.1, OSHA, Eurovent, FM Approved; Coil Material Copper (7× thermal conductivity of HDG steel); Configuration Induced Draft Crossflow Fill/Coil Hybrid
Recold JT Forced Draft Cooling Tower Blower Drive Safety Factor 150% of rated bhp; Configuration Forced draft, low profile; Fan Bearing Life 200,000 hours average
Marley PPWD Hybrid Plume Abatement Hybrid Plume Abatement Cooling Tower Casing/Structure Options FRP, concrete, or wood; Configuration Types Cell-type forced draft, cell-type induced draft, or circular forced draft; Flow Rate 3,000–250,000 gpm
Marley 800 Natural Draft Natural Draft Field-Erected Cooling Tower Configuration Field-erected, natural draft (no fans), hyperbolic shell; Flow Rate 3,000–500,000 gpm; Installed Base More than 275 worldwide
Marley Round Hybrid Plume Abatement Natural Draft Plume Abatement Cooling Tower Application Higher flow rates, saltwater compatible; Design Circular hybrid, hyperbolic shell, natural draft effect; Flow Rate 3,000–500,000 gpm
Marley ClearSky Plume Abatement Plume Abatement Cooling Tower Configuration Back-to-back, fully integrated, retrofit compatible; Flow Rate 3,000–250,000 gpm; Heat Exchanger Material PVC heat exchanger modules in tower plenum
Marley Round Forced Draft Round Forced Draft Cooling Tower Design Round forced draft, hyperbolic shell with natural draft support; Flow Rate 1,200–250,000 gpm; Salt Water Compatible Yes