ATEX/IECEx ClassificationEx ec IIC T5/T4 Gc | Ex tb IIIC T95°C Db
Battery BackupOptional; self-testing (30s monthly, 90-180 min annual)
Class I Division 2Groups A, B, C, D
Class II Division 1 & 2Groups E, F, G
Enclosure DesignClamshell with captive swing barrel-nut latch; robust aluminum body
Ingress ProtectionIP66
LED Colour Options3000K 70CRI; 5000K 70CRI; Pure Amber
Marine RatingMarine Rated (US)
Operating Temperature (battery backup)-20 to +50 °C
Operating Temperature (standard >120W)-50 to +55/+65 °C
Operating Temperature (standard ≤120W)-50 to +40 °C
Optic ChoicesNormal Distribution (~6x6 beam); Extra Wide; Narrow
Type RatingType 3, 4x
Zone RatingZone 2 & Zone 21