Chromalox
25 models - manufacturer-sourced specifications, datasheets and manuals.
| Model | Type | Key specs | Documents |
|---|---|---|---|
| C-DD Deep Draw Cartridge Heaters | Cartridge Heater | Construction Method Deep Drawn — No Weld Seams; Sheath Material Options 304 or 316 Stainless Steel; Surface Treatment Passivated or Electropolished | Datasheet |
| CIR Insertion Cartridge Heaters | Cartridge Heater | Diameter Range 1/4 - 3/4 in; Maximum Operating Temperature 1500 °F | |
| CTC1 & CTC2 Digital Heat Trace Controllers | Commercial Heat Trace Controller | Certifications CE, UL, cUL; Control Modes PID, On/Off, Manual; Current per Circuit 40 A | Datasheet Manual |
| CPR Commercial Self-Regulating Heat Trace Cable | Commercial Self-Regulating Heat Trace Cable | GFEP Requirement 30 mA minimum trip level; Maximum Continuous Exposure Temperature 185 °F; Pipe Compatibility Metal Pipes, Plastic Pipes, Roofs, Gutters | Datasheet |
| CWM Constant Wattage Medium Temperature Heating Cable | Constant Wattage Heat Trace Cable | Heating Element Nichrome wire on parallel buss wires; Jacket Material Fluoropolymer; Maximum Circuit Length 780 ft | Datasheet |
| PHD & PHDT Heavy Duty Fiberglass Woven Drum Heaters | Drum Heater | Attachment Method Spring Clasp; Construction Material Fiberglass Insulated Resistance Wire in Silicone Rubber | Datasheet |
| CHPES-A Medium Pressure Modular Steam Boiler | Electric Steam Boiler | CSSB-A Water Type De-ionized, demineralized or distilled; Certifications UL Listed, CSA (207901), CE/PED; Feed Water Temperature Range 40 to 200 °F | Datasheet |
| Fintube Finned Tubular Heaters (FTS/FTI/SFTS/SFTI) | Finned Tubular Heater | Fin Construction Furnace Brazed; Sheath Material Options Aluminum Painted Steel, Stainless Steel, or MONEL; Standard Element Diameters 0.315 and 0.475 in | |
| CHD/CTRH/CBH Heavy Duty Cartridge Heaters | Heavy Duty Cartridge Heater | Maximum Continuous Sheath Temperature 2000 °F; Sheath Material INCONEL 600; Voltage Options 120, 208, 240, 480 V | Datasheet |
| MaxiZone Multicell Heaters | High Temperature Cartridge Heater | Maximum Continuous Sheath Temperature 2000 °F; Number of Heating Zones 2 or 3; Sheath Material Inconel 600 | Datasheet |
| ADH & ADHT Flanged Duct Heaters | Industrial Duct Heater | ADH Series Maximum Temperature 800 °F; ADHT Series Maximum Temperature 1200 °F; CSA Certification 040859 | Datasheet |
| ITC1 & ITC2 Digital Heat Trace Controllers | Industrial Heat Trace Controller | Certifications CE, UL, cUL; Communications Modbus RTU/RS485, RS422 & TCP/Ethernet; Current per Circuit 40 A | Datasheet Manual |
| ITAS & ITLS Ambient and Line Sensing Control Panels | Industrial Heat Trace Power Control Panel | Base Circuit Capacity 2-48 circuits; Certifications UL, cUL Listed; Optional CE; Current per Circuit 40 A | Datasheet Manual |
| Isopad IT-FG200 Polymer Insulated Heating Tape | Industrial Heating Tape | Maximum Temperature Rating 180 °C; Minimum Bending Radius 25 mm; Nominal Power Output 10-40 W/m | Datasheet Manual |
| Isopad IT-H Fiberglass Insulated Heating Tape | Industrial Heating Tape | Electrical Insulation Material Silica-Glass-fiber; Ingress Protection Rating IP20; Maximum Temperature Rating 900 °C | Datasheet Manual |
| Isopad IT-ITH Fiberglass Insulated Heating Tape | Industrial Heating Tape | Electrical Insulation Material Glass-fiber; Ingress Protection Rating IP20; Maximum Temperature Rating 450 °C | Datasheet Manual |
| MI Mineral Insulated High Temperature Heating Cable | Mineral Insulated Heat Trace Cable | Insulation Material Magnesium Oxide; Maximum Exposure Temperature 1200 °F; Maximum Voltage 600 V | Datasheet |
| Pick & Ship Circulation Heaters | Process Circulation Heater | Available Watt Densities 7.5, 15, 25, 45 W/in²; Certifications UL / cCSAus; Element Material INCOLOY 800 | Datasheet |
| A/HSN/HSW/RHSW Ring Heaters | Ring Heater | Inner Diameter Range 0.5 to 8.5 in; Maximum Temperature Rating 1200 °F; Outer Diameter Range 2.5 to 11 in | |
| ACPC Advanced Modular SCR Power Controller | SCR Power Controller | Amperage Range 40 to 600 A; Firing Modes Zero Cross and Phase Angle; Input Signal Options 0-5V, 0-10V, 0-20mA, 4-20mA, PWM, 1-10kΩ potentiometer | Datasheet |
| SRL Self-Regulating Low Temperature Heating Cable | Self-Regulating Heat Trace Cable | Braid Material Tinned Copper; Bus Wire Gauge 16 AWG; GFEP Requirement 30 mA minimum trip level | Datasheet |
| SRME Self-Regulating Medium Temperature Heating Cable | Self-Regulating Heat Trace Cable | Bus Wire Gauge 16 AWG; Maximum Continuous Exposure Temperature 420 °F; Pipe Compatibility Metallic Pipes Only | Datasheet |
| SRP Self-Regulating Process Temperature Heating Cable | Self-Regulating Heat Trace Cable | Braid Material Tinned Copper; Bus Wire Gauge 16 AWG; Maximum Continuous Exposure Temperature 275 °F | Datasheet |
| C1ZF Single Phase SSR | Solid State Relay | Certifications UL, cUL, CE; Firing Mode Zero Crossover; Maximum Current 120 A | Datasheet |
| C2ZF & C3ZF Three Phase SSR | Solid State Relay | C2ZF Maximum Current 75 A; C3ZF Maximum Current 65 A; Certifications UL, cUL, CE | Datasheet |