Cooling Tower

A cooling tower rejects heat from condenser or process water to the atmosphere by evaporation: warm water spreads over fill media while a fan draws air through it, cooling the water for return to chillers or process loops. The catalog lists 78 models from brands including Marley, Evapco, Baltimore Aircoil Company, Thermal Care, Delta Cooling Towers, Tower Tech, and Recold.

77
Modèles
Sized by ton
Nominal capacity
6
Marques
Cooling Tower

Fonctionnement

Warm water from the condenser loop distributes over fill — thin sheets or splash surfaces that maximize air-water contact. A fan moves air through the fill, evaporating a small fraction of the water and carrying the heat away; the cooled water collects in a basin and pumps back to the load. Drift eliminators capture entrained droplets, and makeup water replaces evaporation and blowdown. Closed-circuit variants keep process fluid inside a coil, spraying water over the coil so the loop stays clean while heat still leaves by evaporation.

Types et variantes

Open-circuit induced-draft towers
The standard configuration — a top fan pulls air through fill in direct water contact.
Forced-draft towers
Fans push air into the tower; common in compact and indoor-ducted designs.
Closed-circuit fluid coolers
Coil-isolated loops for clean process fluid with evaporative performance.
Portable and temporary towers
Skid- or trailer-mounted towers for outages, shutdowns, and project loads.
Crossflow and counterflow designs
Air path geometries trading height, footprint, and maintenance access.

Spécifications clés

SpécificationPlage typiqueSignification
Nominal capacitySized by tonHeat rejection rating matched to the chiller or process load.
Design water flowVaries by model and capacityThe gpm the tower is rated to cool through its design temperature range.
Fan powerVaries by model and capacityDrives airflow and thus thermal performance and sound level.
Approach temperatureVaries by selection and site conditionsHow close the leaving water gets to ambient wet-bulb — the core performance measure.

Comment l'industrie le dimensionne

Cooling towers are sized by heat rejection in nominal tons at design wet-bulb, flow, and range. Selection matches the chiller or process load at the site's design wet-bulb temperature, then checks footprint, water treatment, and electrical supply. Units from 0 to 200 tons reject heat from a single water-cooled chiller or one process loop; 200 to 500 ton units serve as standard temporary towers for a building's chilled water plant during an outage; 500 to 1,000 ton towers handle large plant and process cooling — usually two or more chillers on one tower; units above 1,000 tons provide plant-scale heat rejection for refinery, power, and data-centre turnarounds.

Applications

  • Condenser water cooling for chiller plants
  • Process cooling for manufacturing and industrial loads
  • Temporary heat rejection during shutdowns and tower replacements
  • Data center and campus central plant support
  • Supplemental capacity for peak-season loads

Sécurité et opération

  • Cooling towers can harbor Legionella; ASHRAE 188 water management programs — treatment, monitoring, cleaning — are the controlling practice.
  • Fan and pump lockout precedes any basin, fill, or mechanical work.
  • Tower access involves work at height; ladders, platforms, and fall protection follow OSHA requirements.
  • Chemical water treatment is handled per its hazard documentation, away from drift and intake paths.

Normes et certifications

CTI · STD-201
Thermal performance certification for evaporative heat rejection equipment.
ASHRAE · 188
Legionellosis risk management for building water systems, including cooling towers.
NFPA · 214
Fire protection standard for water-cooling towers.

Questions fréquentes

How much water does a tower consume?
Evaporation carries away roughly the heat load's equivalent in water, plus blowdown to control dissolved solids. Makeup water supply and treatment are part of every installation plan.
Open or closed circuit — how is the choice made?
Open towers are simpler and cheaper per ton; closed-circuit fluid coolers keep the process loop sealed and clean at some performance and cost premium — decisive where loop fouling is unacceptable.
What is approach and why does it matter?
The gap between leaving water temperature and ambient wet-bulb. Tight approaches need more fill and fan — a tower cannot cool below wet-bulb, so local climate bounds the achievable water temperature.

Parcourir par fabricant

Sources

Chaque spécification est vérifiée par rapport aux données publiées par le fabricant, avec la source liée pour référence.

Tous les modèles

77 modèles · Page 1 sur 2 · Chaque spécification citée à la source

Tower Tech TTXR Series
Tower Tech · Open Circuit Cooling Tower
Tower Tech TTXL Series
Tower Tech · Open Circuit Cooling Tower
Tower Tech TTCC-FC Series
Tower Tech · Closed Circuit Evaporative Fluid Cooler
Delta Cooling Towers Paragon
Delta Cooling Towers · Induced Draft Cooling Tower
Delta Cooling Towers Pioneer
Delta Cooling Towers · Forced Draft Cooling Tower
Delta Cooling Towers TM Series
Delta Cooling Towers · Induced Draft Cooling Tower
Delta Cooling Towers TMX Series
Delta Cooling Towers · Induced Draft Cooling Tower
Tower Tech TTCC-HC Series
Tower Tech · Closed Circuit Hybrid Fluid Cooler
Evapco PHW Closed Circuit Cooler
Evapco · Closed Circuit Cooler
Marley AV
Marley · Crossflow Cooling Tower
Marley NC
Marley NC
Marley · Crossflow Cooling Tower
Marley NC Everest
Marley NC Everest
Marley · Crossflow Cooling Tower
Evapco AT Atlas Cooling Tower
Evapco · Cooling Tower
Marley CP
Marley · Counterflow Cooling Tower
Marley CR
Marley · Counterflow Cooling Tower
Marley NX
Marley · Crossflow Cooling Tower
Delta Cooling Towers Anti-Microbial Cooling Tower
Delta Cooling Towers · Induced Draft Cooling Tower (Anti-Microbial)
Delta Cooling Towers DS Delta Dry System
Delta Cooling Towers · Packaged Cooling System (Closed Loop, Plate Heat Exchanger)
Evapco AXS Cooling Tower
Evapco · Cooling Tower
Evapco EAW-VD V Dry Cooler
Evapco · Air-Cooled Closed Circuit Cooler
Evapco ESW4 Closed Circuit Cooler
Evapco · Closed Circuit Cooler
Evapco LPT Cooling Tower
Evapco · Cooling Tower
Evapco LSTE Cooling Tower
Evapco · Cooling Tower
Evapco eco-ATWB-H Hybrid Closed Circuit Cooler
Evapco · Closed Circuit Cooler
Marley MD
Marley MD
Marley · Counterflow Cooling Tower
Marley MD Everest
Marley MD Everest
Marley · Counterflow Cooling Tower
Marley NC Fiberglass
Marley · Crossflow Cooling Tower
Marley Recold JT
Marley · Forced Draft Cooling Tower
Marley Series 10 and Series 15
Marley · Crossflow Field-Erected Cooling Tower
Thermal Care FC610
Thermal Care · Fiberglass Cooling Tower
Thermal Care FC620
Thermal Care · Fiberglass Cooling Tower
Thermal Care FC630
Thermal Care · Fiberglass Cooling Tower
Thermal Care FC640
Thermal Care · Fiberglass Cooling Tower
Thermal Care FC710
Thermal Care · Fiberglass Cooling Tower
Thermal Care FC740
Thermal Care · Fiberglass Cooling Tower
Thermal Care FT8220
Thermal Care · Fiberglass Cooling Tower
Thermal Care FT8250
Thermal Care · Fiberglass Cooling Tower
Thermal Care FT8260
Thermal Care · Fiberglass Cooling Tower
Thermal Care FT8270
Thermal Care · Fiberglass Cooling Tower
Thermal Care FT8280
Thermal Care · Fiberglass Cooling Tower
Evapco ATWB Closed Circuit Cooler
Evapco · Closed Circuit Cooler
Evapco LRWB Closed Circuit Cooler
Evapco · Closed Circuit Cooler
Evapco SUN Cooling Tower
Evapco · Cooling Tower
Evapco eco-LSWE Closed Circuit Cooler
Evapco · Closed Circuit Cooler
Marley AQUATOWER
Marley · Crossflow Cooling Tower
Marley NC Alpha (Splash Fill)
Marley · Crossflow Cooling Tower
Marley Sigma
Marley · Crossflow Field-Erected Cooling Tower
Baltimore Aircoil Company HXV Hybrid Cooler
Baltimore Aircoil Company · Hybrid Cooler
Page 1 sur 2 Suiv. →