Aller au contenu
Catalogue
← Heaters

Electric Heater

An electric heater converts electrical power to heat through resistance elements with a fan spreading the warmth — no combustion, no fumes, no fuel logistics — making it the default for enclosed and occupied spaces where air quality matters. The catalog lists 123 models from brands including Qmark, Dimplex, Chromalox, TPI Corporation and Val6.

123
Modèles
5,000 through 400,000 BTU across the catalog size classes
Heat output
14
Marques
Electric Heater

Fonctionnement

Current through resistance elements produces heat with near-total conversion efficiency at the unit; a fan moves air across the elements into the space. Output is fixed by the electrical supply — every BTU corresponds to electrical power drawn — so the practical ceiling is the site's available circuits, not the heater catalog. Smaller units plug into standard circuits, while larger salamander and skid formats require high-voltage or three-phase connections installed by qualified electricians.

Types et variantes

Portable fan-forced heaters
Plug-in units for rooms, offices and small work areas.
Electric salamander heaters
High-output jobsite units on higher-voltage supplies.
Fixed unit and wall heaters
Permanently wired heaters for garages, entries and utility spaces.
Industrial process heaters
Chromalox-style element packages for process and freeze-protection duty.

Spécifications clés

SpécificationPlage typiqueSignification
Heat output5,000 through 400,000 BTU across the catalog size classesOutput tracks electrical input directly — the sizing figure.
Airflow50 to 550 cfm documented across listed modelsFan delivery spreads the heat through the space.
Supply requirementDocumented per model listingVoltage, phase and amperage decide which site circuits can host the unit.
StagingDocumented per model listingElement stages let output match partial loads without cycling.

Comment l'industrie le dimensionne

Electric heaters are sized in BTU against the space's heat loss, but the governing constraint is electrical supply: the catalog classes — 5,000-50,000, 50,000-150,000 and 150,000-400,000 BTU — climb from standard-circuit portables to units needing dedicated high-voltage or three-phase service. Site power is confirmed before the class is chosen.

Applications

  • Heating enclosed and occupied spaces without combustion fumes
  • Drying interiors after paint, drywall and flooring work
  • Job trailers, offices and small workshops
  • Supplemental and freeze-protection heat
  • Warehouse and shop heating where power is available

Sécurité et opération

  • Circuit loading is the class's core hazard — heaters draw at capacity continuously, and undersized or daisy-chained cords overheat.
  • Clearances to combustibles per the data plate apply; elements run hot enough to ignite what touches them.
  • Units stand on stable, dry surfaces with cords protected from traffic, on GFCI supply in damp work.
  • Large units are hard-wired or connected by qualified electricians to the nameplate specification.

Normes et certifications

UL · 1025
Safety standard for electric air heaters.
NFPA · 70 (NEC)
Circuit sizing, cord and connection requirements.
OSHA · 29 CFR 1926.154
Temporary heating device rules on construction sites.

Questions fréquentes

Why choose electric over fuel-fired heat?
Clean air, zero fuel logistics and quiet, unattended-tolerant operation in enclosed or occupied spaces. The limits are electrical supply and cost per BTU relative to fuel.
What supply do the larger classes need?
Beyond the plug-in class, units documented in the 50,000-150,000 and 150,000-400,000 BTU classes require dedicated high-voltage, often three-phase circuits — an electrician's installation, confirmed against the model listing.
Are electric heaters really fume-free?
Yes — no combustion occurs. Dust burning off elements on first start is the only air effect, which is why they serve occupied buildings, food spaces and finish-sensitive work.

Comparer les modèles populaires

Chercher par spécification →

Normalisé aux mêmes unités. Un tiret signifie que la valeur n'a pas été publiée.

ModèleDébit d’airCapacité de carburant
Multiquip EHTX-44Y5 --
Val6 MPX 110 cfm6.6 gal

Équipements connexes

Parcourir par fabricant

Sources

Chaque spécification est vérifiée par rapport aux données publiées par le fabricant, avec la source liée pour référence.

Tous les modèles

123 modèles · Page 3 sur 3 · Chaque spécification citée à la source

Esab SDE-100
Esab · Drying Oven
Esab SDE-250
Esab · Drying Oven
Esab SDF-50
Esab · Drying Oven
Modine Amp Dawg AMP090
Modine · Electric Unit Heater
Qmark CSH Series
Qmark · Commercial Sill-Height Convector
Qmark SSAR Series
Qmark · Architectural SmartSeries Programmable Wall Heater
100 cfm
TPI Corporation 474 Series
TPI Corporation · Portable Electric Heater (240V)
Chromalox A/HSN/HSW/RHSW Ring Heaters
Chromalox · Ring Heater
Esab SDE-50
Esab · Drying Oven
Qmark DSH Series
Qmark · Decorative Sill-Height Convector
Qmark Thermazone Series
Qmark · Commercial/Residential Infrared Heater
Qmark Thermazone Thin Series
Qmark · Commercial/Residential Infrared Heater
Chromalox C-DD Deep Draw Cartridge Heaters
Chromalox · Cartridge Heater
Chromalox CHD/CTRH/CBH Heavy Duty Cartridge Heaters
Chromalox · Heavy Duty Cartridge Heater
Chromalox MaxiZone Multicell Heaters
Chromalox · High Temperature Cartridge Heater
Dewalt DXH1000TS
Dewalt · Heaters
Chromalox CIR Insertion Cartridge Heaters
Chromalox · Cartridge Heater
Chromalox PHD & PHDT Heavy Duty Fiberglass Woven Drum Heaters
Chromalox · Drum Heater
Dewalt DXH40FA
Dewalt · Heaters
Dewalt DXH65FAV
Dewalt · Heaters
Multiquip EHTX-44Y5
Multiquip
Qmark MUH0371
Qmark · Electric Heater
Qmark MUH0521
Qmark · Electric Heater
Qmark MUH0541
Qmark · Electric Heater
Qmark MUH0571
Qmark · Electric Heater
Qmark MUH072
Qmark · Electric Heater
Qmark MUH108
Qmark · Electric Heater
← Préc. Page 3 sur 3