Towable Diesel Generator

A towable diesel generator is a trailer-mounted, self-contained electrical power generation unit equipped with a diesel engine, alternator, fuel tank, and control panel. These units deliver temporary, portable electrical power to construction sites, industrial facilities, and emergency backup applications where utility power is unavailable or inadequate. Configured for highway transport behind a standard pickup or truck, they range from compact units to multi-megawatt systems requiring flatbed transport.

114
Modèles
3.5–593.9 kVA
Power Output (kVA)
24
Marques
Towable Diesel Generator

Cat classes

Choisissez une classe de taille — la capacité et la portée varient selon la gamme.

Fonctionnement

The diesel engine drives a brushless alternator to convert mechanical energy into electrical power. The engine draws fuel from an integral tank, typically sized for 12 to 48 hours of runtime at full load, while an automatic voltage regulator maintains stable output voltage and frequency. Most units include a control panel with circuit breakers, outlets, and hour meters; many feature automatic start/stop capability and load-management controls. The trailer chassis provides structural support, weather protection, and road-legal towing hardware including axles, brakes, and lighting. Sound-attenuated enclosures reduce noise emissions, while integrated lifting eyes and forklift pockets facilitate positioning. Load bank testing and generator connection typically occur via twist-lock or cam-lock receptacles, with output configurations spanning 120/240V single-phase to 480V three-phase.

Types et variantes

Open-Frame Towable Generator
Exposed engine and alternator mounted on a basic trailer chassis; lighter and more economical, used where noise and weather are secondary concerns.
Sound-Attenuated Towable Generator
Enclosed in a weather-resistant, sound-dampening canopy; standard for urban sites and residential areas where noise ordinances apply.
Tier 4 Final Compliant Generator
Equipped with modern diesel engines meeting EPA Tier 4 Final emissions standards through diesel particulate filters and selective catalytic reduction.
Prime Power Generator
Rated for continuous duty with unlimited run hours per year; heavier-duty components and larger cooling systems than standby-rated units.
Paralleling Towable Generator
Equipped with synchronizing controls and hardware to operate multiple units in parallel, enabling scalable power for large temporary loads.

Spécifications clés

SpécificationPlage typiqueSignification
Power Output (kVA)3.5–593.9 kVAThe continuous electrical output capacity, determining the maximum load the generator can support; the primary sizing metric.
Fuel Capacity1.6–275.0 galOnboard diesel fuel storage, determining runtime between refueling; larger tanks support extended unattended operation.
Rated Frequency60 HzThe electrical output frequency; North American standard is 60 Hz, determining compatibility with connected equipment.
Rated Voltage120–480VThe electrical output voltage configuration; determines compatibility with site distribution equipment and connected loads.
Engine Displacement49.4–389.0 cm³The total swept volume of all engine cylinders, correlating with power output and fuel consumption characteristics.

Comment l'industrie le dimensionne

The industry sizes towable diesel generators by continuous kilowatt (kW) output, the maximum electrical load the unit can sustain indefinitely. Common classifications include up to 25 kW for site trailers, light plants, or single pumps left for weeks; 25–60 kW for trailer complexes, multiple pumps, or small hoists; 60–150 kW for whole-site construction power including hoists, trailers, task lighting, and tools; 150–300 kW for building temporary service during utility cutovers or large process loads; 300–600 kW for hospitals, data centers, or plant turnarounds shipped on lowboys; 600–1,250 kW for utility-scale temporary power, usually paralleled and fed into distribution packages; and 1,250+ kW for plant-scale prime power and grid support with synchronized units. Standby ratings, expressed 10–15% higher than prime ratings, reflect short-duration peak capacity for emergency use. Load calculation includes the sum of all connected equipment plus a diversity factor accounting for simultaneous demand.

Applications

  • Construction site power for temporary distribution panels, hoists, tools, and trailers before permanent utility service
  • Industrial plant turnarounds and shutdowns requiring temporary power during equipment maintenance or upgrades
  • Emergency backup power for hospitals, data centers, and critical facilities during utility outages or service transfers
  • Event power for outdoor festivals, concerts, and sporting events lacking permanent electrical infrastructure
  • Pipeline and well-site operations powering pumps, compressors, and process equipment in remote locations
  • Disaster recovery and emergency response providing temporary power to damaged or off-grid areas

Sécurité et opération

  • Maintain minimum clearances around the generator enclosure for cooling airflow and exhaust dispersal; carbon monoxide accumulation poses a lethal hazard in enclosed or poorly ventilated areas
  • Verify ground fault protection and proper grounding of the generator frame and neutral conductor before energizing connected loads
  • Confirm fuel and oil levels, coolant condition, and battery charge during pre-start inspection; monitor gauges during operation for overheating or low oil pressure
  • Use listed load cables and connectors rated for the generator's output amperage; inspect for damage before each connection to prevent arc flash or electrocution
  • Follow NFPA guidelines for diesel fuel storage and dispensing; maintain a fire extinguisher near the unit and prohibit smoking or open flames within 25 feet

Normes et certifications

NFPA · NFPA 110: Standard for Emergency and Standby Power Systems
Establishes installation, maintenance, and testing requirements for standby and emergency power systems including towable generators.
EPA · Tier 4 Final Emissions Standards
Federal regulations governing nitrogen oxide and particulate matter emissions from non-road diesel engines, phased in by horsepower class.
OSHA · 29 CFR 1926.404
Wiring design and protection requirements for temporary electrical installations on construction sites, including generator output protection.

Questions fréquentes

What is the difference between prime and standby power ratings?
Prime power ratings indicate the generator can operate continuously at that load with unlimited annual hours, while standby ratings reflect maximum output for emergency use limited to 200 hours per year with variable load. Prime-rated units feature heavier alternators, larger cooling systems, and more conservative engine loading.
How is generator size determined for a construction site?
Calculate the sum of all connected loads in kW, applying demand factors for non-simultaneous use, then add 20–25% margin for motor starting inrush and future expansion. Large motor loads require additional capacity—typically three to six times the motor's running kW—during the starting period.
What maintenance intervals apply to towable diesel generators?
Daily or pre-start checks include fluid levels, visual inspection, and load bank connection verification. Oil and filter changes occur every 250–500 hours depending on load factor, while fuel filters, air filters, and coolant follow manufacturer intervals. Annual load bank testing verifies output capacity and governor response.
What towing and transport requirements govern towable generators?
Units under 10,000 lbs typically tow behind standard pickups with Class III or IV hitches and 7-pin connectors; larger units require medium-duty trucks or tractors. Generators exceeding 20,000 lbs often require commercial driver's licenses, oversize permits, and flatbed transport depending on state regulations.

Comparer les modèles populaires

Chercher par spécification →

Normalisé aux mêmes unités. Un tiret signifie que la valeur n'a pas été publiée.

ModèlePuissance de sortieCapacité de carburant
Multiquip GAW135H 1.9 kVA1.6 gal
Generac MDG150DF4 120.0 kVA-
Generac MGG210N2 185.0 kVA-
Generac MDE330 264.0 kVA-
Generac MGG450 360.0 kVA-
Honda EU2200i Companion -95.0 gal

Équipements connexes

Parcourir par fabricant

Sources

Chaque spécification est vérifiée par rapport aux données publiées par le fabricant, avec la source liée pour référence.

Tous les modèles

114 modèles · Page 1 sur 3 · Chaque spécification citée à la source

Dragon Products Dragon 400KW
Dragon Products · Generator
Seacube Typical Undermount Genset
Seacube Typical Undermount Genset
Seacube · Genset
50.0 gal
Honda EB10000
Honda EB10000
Honda · generator
8.2 gal
Honda EB2200i
Honda EB2200i
Honda · generator
95.0 gal
46.3 lb (21 kg)
Honda EB5000
Honda EB5000
Honda · generator
6.2 gal
Honda EB6500
Honda EB6500
Honda · generator
6.2 gal
Honda EG4000
Honda EG4000
Honda · generator
6.3 gal
148 lb (67 kg)
Honda EM5000SX
Honda EM5000SX
Honda · generator
6.2 gal
Honda EM6500SX
Honda EM6500SX
Honda · generator
6.2 gal
Honda EU1000i
Honda EU1000i
Honda · generator
0.6 gal
28.7 lb (13 kg)
Honda EU2200i
Honda EU2200i
Honda · generator
95.0 gal
Honda EU2200i Companion
Honda EU2200i Companion
Honda · generator
95.0 gal
46.3 lb (21 kg)
Honda EU3000iS
Honda EU3000iS
Honda · generator
3.4 gal
130 lb (59 kg)
Honda EU3200i
Honda EU3200i
Honda · generator
1.2 gal
59.5 lb (27 kg)
Honda EU7000iS
Honda EU7000iS
Honda · generator
5.1 gal
262 lb (119 kg)
Ironton 504000
Ironton · Generator
3.9 gal
Seacube Typical Clip-On Genset
Seacube Typical Clip-On Genset
Seacube · Genset
130.0 gal
IHI LM2500 Series
IHI LM2500 Series
IHI · Gas Turbine Power Generation System
Altrad Belle GPX Range
Altrad Belle GPX Range
Altrad Belle · Generator
5.6 gal
Triton Thermo King SG-5000
Triton · Generator Set
Triton Carrier RG15
Triton · Generator Set
120.2 gal
Altrad Belle GPX CTE Range
Altrad Belle GPX CTE Range
Altrad Belle · Generator
Multiquip G55H
Multiquip · Equipment
Thermo King TriPac APU (3rd Generation)
Thermo King TriPac APU (3rd Generation)
Thermo King · Diesel Auxiliary Power Unit
Briggs & Stratton EXi625 Push Mower Engine
Briggs & Stratton · Small Engine
Briggs & Stratton EXi725 Push Mower Engine
Briggs & Stratton · Small Engine
Briggs & Stratton EXi875 Push Mower Engine
Briggs & Stratton · Small Engine
Wyco 3-Phase Generator
Wyco · High-Cycle Generator
Algeco Generator Hire (10-500kVA)
Algeco · Generator
Thermo King TriPac Envidia (2nd Generation)
Thermo King · All-Electric Auxiliary Power Unit
Matco Tools PQP01001
Matco Tools PQP01001
Matco Tools · Generator
Dewalt DXGNI2200
Dewalt · Generators
Dewalt DXGNR4000
Dewalt · Generators
121 lb (55 kg)
Dewalt DXGNR6500
Dewalt · Generators
Dewalt DXGNR8000
Dewalt · Generators
Dragon Products PowerGR26M
Dragon Products · Generator
Dragon Products PowerGT43M
Dragon Products · Generator
Matco Tools PQP03609
Matco Tools PQP03609
Matco Tools · Generator
Generac 5000W
Generac · Diesel Generator
Kubota GL11000-USA
Kubota · Diesel Generator
Kubota GL14000
Kubota · Diesel Generator
Kubota KJ-S150VX
Kubota · Diesel Generator Set
Kubota KJ-T160DX
Kubota · Diesel Generator Set
Kubota KJ-T210VX
Kubota · Diesel Generator Set
Multiquip EGC-1000DD
Multiquip
38,460 lb (17,445 kg)
Multiquip EGC-750DD
Multiquip
37,545 lb (17,030 kg)
Multiquip G-29R
Multiquip
Multiquip GAW135H
Multiquip · Equipment
1.9 kVA
1.6 gal