Full specifications
| AFUE | Up to 96% AFUE | ↗ |
| Cabinet Air Leakage | ≤ 2% | ↗ |
| Electrical Supply | 115 VAC, 60 Hz, single-phase | ↗ |
| Gas Connection | ½" FPT | ↗ |
| Gas Valve | Two-stage gas valve | ↗ |
| Heat Exchanger | Heavy-duty stainless-steel tubular | ↗ |
| Heating Input | 40,000 –120,000 BTU/h | ↗ |
| High Fire Input | 40,000-120,000 BTU/h | ↗ |
| High Fire Output | 38,440-115,320 BTU/h | ↗ |
| Min Circuit Ampacity | 7.8-14.4 amps | ↗ |
| Motor Type | Variable-speed ECM | ↗ |
| Shipping Weight | 116–158 lbs (52.6–71.7 kg) | ↗ |
| Vent Diameter | 2" - 3" | ↗ |