← Air Handlers

Air Handler

An air handler is the fan-and-coil assembly that moves conditioned air through a building: a blower drives air across heating or cooling coils and filters, into ductwork. It pairs with condensing units, heat pumps, chillers or hydronic plants rather than generating heating or cooling itself. The catalog lists 91 models from brands including Goodman, Carrier, Trane, Lennox, McQuay and Johnson Controls.

78
Modelos
Sized by ton across cataloged models
Capacity
10
Marcas
Air Handler

Cómo funciona

Return air enters through filters, passes across a coil — refrigerant evaporator, chilled water or hot water — and the blower delivers it to supply ductwork. Electric heat strips can back up heat pump coils. Condensate from cooling coils drains through a trapped line with overflow protection. Larger commercial handlers are built in sections: mixing boxes blending return and outside air, filter banks, coils, and fan sections, assembled to the project's airflow and ventilation specification.

Tipos y variantes

Residential and light commercial fan-coil units
Matched indoor units for split systems and heat pumps.
Modular commercial air handlers
Sectional units built up from mixing, filter, coil and fan modules.
Makeup air units
Handlers that condition outside air to replace exhausted building air.
Temporary and portable handlers
Units deployed with temporary chillers and heat sources on projects and recovery work.

Especificaciones clave

EspecificaciónRango típicoQué significa
CapacitySized by ton across cataloged modelsTonnage determines heating or cooling delivery matched to the space load.
AirflowTypically 400 cfm per ton of coolingDelivered air volume matched to load and duct design.
Coil typeRefrigerant, chilled water or hot waterCoil type determines which plant the handler pairs with.
External static pressureVaries by model and fan selectionThe duct resistance the blower can overcome while delivering rated airflow.

Cómo la industria lo dimensiona

Air handlers are sized by cooling or heating capacity in tons, then matched to airflow in cfm against the space's load and the duct system's static pressure. The industry pairs handlers with the plant — refrigerant, chilled water or hot water source. Coil rows, filter depth and fan curves are selected from manufacturer data for the design conditions. A 0–10 ton handler blows chilled water cooling into one room or a small office suite and pairs with a 10 to 20 ton chiller. A 10–25 ton unit conditions a floor, a large tent, or a production area off a mid-size chiller. A 25–50 ton handler serves a large open space — warehouse, hangar, or process area — on a single chilled water loop. Units above 50 tons provide building-scale air handling; several units are usually fed from one large chiller.

Aplicaciones

  • Central air distribution for residential and commercial systems
  • Chilled and hot water air distribution in hydronic plants
  • Makeup air for kitchens, labs and industrial exhaust
  • Temporary conditioned air on construction and restoration projects
  • Ventilation air delivery in commercial buildings

Seguridad y operación

  • Fan sections are locked out before any coil, filter or belt work — blowers start on remote calls.
  • Condensate drains are trapped and tested; overflowing pans above ceilings are a major water damage source.
  • Refrigerant coil connections are serviced only by EPA Section 608 certified technicians.
  • Access doors on pressurized sections are latched; an open door on a running fan section is a projectile hazard.

Normas y certificaciones

AHRI · 430
Performance rating of central station air handling units.
ASHRAE · 62.1
Ventilation for acceptable indoor air quality — governs outside air delivered by handlers.
UL · 1995
Safety standard for heating and cooling equipment.

Preguntas frecuentes

What is the difference between an air handler and a furnace?
A furnace generates heat by combustion and moves air; an air handler only moves air across coils fed by external equipment — condensing unit, heat pump or hydronic plant — optionally with electric backup strips.
How is an air handler matched to a condensing unit?
Through manufacturer-rated combinations: coil and blower must match the outdoor unit's capacity and refrigerant so the rated performance and warranty hold.
Why does static pressure matter?
Ducts resist airflow. A blower selected below the system's static pressure delivers less air than rated, starving rooms and icing coils; the fan curve must meet the duct design.

Explorar por fabricante

Fuentes

Cada especificación se verifica con los datos publicados por el fabricante, con la fuente enlazada como referencia.

Todos los modelos

78 modelos · Página 2 de 2 · Cada especificación citada a la fuente

AAON V3 Series
AAON · Vertical Indoor Air Handling Unit
Carrier F55
Carrier · 115V Comfort Air Handler
Carrier FE5B
Carrier · Infinity Variable-Speed Air Handler
Carrier FJ5
Carrier · Comfort Air Handler
Carrier FMA5L
Carrier · Multi-Family Standard-Efficiency Air Handler
Carrier FMA5X
Carrier · Multi-Family High-Efficiency Air Handler
Carrier FMC5S
Carrier · Multi-Family Cased Air Handler
Carrier FMC5X
Carrier · Multi-Family Cased Air Handler
Carrier FMC5Z
Carrier · Multi-Family Cased Air Handler
Carrier FMU5S
Carrier · Multi-Family Uncased Air Handler
Carrier FMU5X
Carrier · Multi-Family Uncased Air Handler
Carrier FMU5Z
Carrier · Multi-Family Uncased Air Handler
Carrier FT5
Carrier · Performance Air Handler
Goodman AVPEC
Goodman · Air Handler
Johnson Controls J07-20NL
Johnson Controls · Air Handler
Johnson Controls J07-20NM
Johnson Controls · Air Handler
Johnson Controls J25NC
Johnson Controls · Air Handler
Johnson Controls J30-50ND
Johnson Controls · Air Handler
Lennox CBA25UHE
Lennox · Air Handler
Lennox CBA25UHV
Lennox · Air Handler
Lennox CBA27UHE
Lennox · Air Handler
Lennox CBK43UHET
Lennox · Air Handler
Lennox CBK45UHET
Lennox · Air Handler
Lennox CBK45UHPT
Lennox · Air Handler
Trane 5TEM4B02AC21SA
Trane · Air Handler
Trane 5TEM4B03AC31SA
Trane · Air Handler
Trane 5TEM4B04AC31SA
Trane · Air Handler
Trane 5TEM4D05AC41SA
Trane · Air Handler
Trane 5TEM4D06AC41SA
Trane · Air Handler
Trane 5TEM4D07AC51SA
Trane · Air Handler
← Ant. Página 2 de 2