Ir al contenido
Heyquip Heyquip Catálogo
← Heaters

Direct Fired Heater

A direct fired heater burns fuel, typically propane or natural gas, directly in the airstream it delivers, putting nearly all the fuel's energy into the space as heat. The tradeoff is that combustion products enter the heated air, so these heaters belong in open, well-ventilated spaces. The catalog lists 142 models from brands including Modine, Master, Remington, Trane, Qmark and Lennox.

142
Modelos
Up to 50,000 through 400,000 BTU + across the catalog size classes
Heat output
20
Marcas
Direct Fired Heater

Cómo funciona

A burner fires into the airflow from an integral fan; air passes through the flame zone and carries the heat, and the combustion byproducts, into the space. With no heat exchanger, efficiency approaches the fuel's full value and the equipment stays simple, light and inexpensive per BTU. Because carbon monoxide, carbon dioxide and water vapor discharge with the heated air, ventilation requirements are absolute: fixed fresh-air openings or mechanical ventilation sized per the manufacturer and applicable code.

Tipos y variantes

Portable forced-air heaters
Compact propane and gas units for spot and small-area heat.
High-output construction heaters
Large box and salamander formats for open structures and enclosures.
Suspended unit heaters
Fixed gas-fired heaters for garages and industrial bays.
Tent and ground-thaw configurations
Ducted direct-fired setups for temporary structures and frozen ground.

Especificaciones clave

EspecificaciónRango típicoQué significa
Heat outputUp to 50,000 through 400,000 BTU + across the catalog size classesBTU per hour: the sizing figure against space volume and temperature rise.
Airflow150 to 2,182.5 cfm documented across listed modelsDelivered air volume spreads the heat through the space.
Fuel typeDocumented per model listingPropane, natural gas or dual-fuel decides supply logistics.
Fuel capacity7 to 20 gal documented on tank-equipped modelsOnboard fuel sets run time between refills where cylinders are not used.

Cómo la industria lo dimensiona

Direct fired heaters are sized in BTU per hour against space volume, target temperature rise and air exchange; the catalog classes run Up to 50k, 50-150k, 150-400k and 400k BTU +. Every selection carries a ventilation check: the size that heats the space must also have the fresh-air openings the manual requires.

Aplicaciones

  • Heating open and well-ventilated construction areas
  • Concrete curing and ground thaw support
  • Tent and temporary structure heat with ducted fresh air
  • Garage, shop and industrial bay heating with fixed unit heaters
  • Spot heat for crews in unenclosed structures

Seguridad y operación

  • Combustion products enter the heated space: carbon monoxide exposure is the class's defining hazard, and ventilation per the manufacturer and OSHA 1926.154 is mandatory, with CO monitoring in enclosed work.
  • Clearances to combustibles are maintained per the data plate; tarps and tent fabric near discharge are recurrent fire causes.
  • Propane cylinders and hoses are handled, secured and leak-checked per NFPA 58.
  • Direct fired units are excluded from sleeping areas and tightly sealed occupied spaces outright.

Normas y certificaciones

OSHA · 29 CFR 1926.154
Temporary heating devices: ventilation, clearance and placement rules.
ANSI · Z83.7 / CSA 2.14
Gas-fired construction heater standard.
NFPA · 58
Liquefied petroleum gas code for propane supply and cylinders.

Preguntas frecuentes

Direct fired or indirect fired: how is the choice made?
Ventilation and air quality. Direct fired delivers more heat per fuel dollar but puts combustion products in the space; indirect fired keeps the airstream clean at lower efficiency. Occupied, enclosed or finish-sensitive work goes indirect.
How much ventilation does a direct fired heater need?
The manufacturer's stated fresh-air opening or exchange for the model: a code obligation. When the required openings defeat the heating goal, the job has outgrown direct fired equipment.
Why does moisture appear on cold surfaces near these heaters?
Combustion produces water vapor along with heat; in cool enclosures it condenses on cold surfaces: a consideration for drying work and finish protection.

Comparar modelos populares

Buscar por especificación →

Normalizado a las mismas unidades. Un guion significa que el valor no fue publicado.

ModeloFlujo de aireCapacidad de combustible
Generac MIH1.2 --
Multiquip HHNG5 -7.0 gal
Multiquip GBHM --
Val6 Hotgun 125NA 636 cfm14.3 gal

Equipos relacionados

Explorar por fabricante

Fuentes

Cada especificación se verifica con los datos publicados por el fabricante, con la fuente enlazada como referencia.

Todos los modelos

142 modelos · Página 3 de 3 · Cada especificación citada a la fuente

Multiquip GBHM
Multiquip · Equipment
→
Multiquip WSHE/MSHE Series
Multiquip · Equipment
→
Trane XC80 Gas Furnace
Trane · Gas Furnace
→
Modine IHR160
Modine · Gas-Fired High-Intensity Indoor Infrared Heater
→
Modine IHR30
Modine · Gas-Fired High-Intensity Indoor Infrared Heater
→
Modine L.B. White Premier 40
Modine · Direct-Fired Portable Forced Air Heater
→
Modine POR100
Modine · Oil-Fired Horizontal Unit Heater
→
Qmark MSPH Series
Qmark · Plenum-Rated Unit Heater
675 cfm
→
Trane 96 Two-Stage Variable Speed Gas Furnace
Trane · Gas Furnace
→
Lennox ML196E
Lennox · Gas Furnace
→
Lennox SL297NV
Lennox · Gas Furnace
→
Modine POR145
Modine · Oil-Fired Horizontal Unit Heater
→
Modine POR185
Modine · Oil-Fired Horizontal Unit Heater
→
Schaefer Zubri Z1-12
Schaefer · Portable Propane Patio Heater
→
Trane 80 Single-Stage Gas Furnace
Trane · Gas Furnace
→
Trane 80 Two-Stage Gas Furnace
Trane · Gas Furnace
→
Lennox EL280E
Lennox · Gas Furnace
→
Trane 15 Two-Stage Gas Furnace/Air Conditioner Packaged
Trane · Gas Furnace/Air Conditioner Packaged Unit
→
Generac MIH1.2
Generac · Mobile Heater
→
← Ant. Página 3 de 3