Ir al contenido
Heyquip Heyquip Catálogo
← Dewatering Pumps

Diaphragm Pump

A diaphragm pump is a positive-displacement pump that moves water by flexing a rubber diaphragm back and forth inside a chamber. Because it has no high-speed impeller, it handles mud, sludge, and debris-laden water that would clog or destroy a centrifugal pump. It can also run dry without damage, which suits seepage and slow-inflow conditions.

79
Modelos
1 to 8 in across cataloged size bands; 2 in and 3 in are the standard contractor sizes
Discharge diameter (in)
13
Marcas
Diaphragm Pump

Cómo funciona

An engine or motor drives a connecting rod that pulls the diaphragm up, drawing water through a one-way inlet valve into the chamber. On the down stroke the diaphragm pushes that water out through a discharge valve. The cycle repeats several times per second, producing a steady pulsing flow. Because each stroke displaces a fixed volume, output is largely independent of the material being pumped. This is why diaphragm pumps are the standard choice for 'mud hog' duty: slurry, leaf-laden water, and seepage with high solids content.

Tipos y variantes

Single-diaphragm engine-driven
The common construction-site configuration; one chamber, gas or diesel engine, wheeled frame.
Double-diaphragm
Two chambers working alternately smooth out the flow pulses and increase capacity.
Air-operated (AODD)
Driven by compressed air rather than an engine; suited to fumes-sensitive or flammable environments.
Electric-drive diaphragm
Motor-driven units for indoor or emissions-restricted work areas.

Especificaciones clave

EspecificaciónRango típicoQué significa
Discharge diameter (in)1 to 8 in across cataloged size bands; 2 in and 3 in are the standard contractor sizesSets hose compatibility and the maximum solids the valves can pass.
Max head (ft)Roughly 13 to 50 ft across cataloged modelsDiaphragm pumps are low-head by design; they move sludge steadily rather than lifting water high.
Engine power (hp)About 7.5 to 28 hp on cataloged engine-driven modelsLarger diaphragms and higher stroke rates need more power.

Cómo la industria lo dimensiona

Diaphragm pumps are sized by discharge diameter and expected inflow. Because flow per stroke is fixed, a small unit keeps pace with slow seepage while larger diameters handle heavier sludge volumes. Sites with steady heavy inflow of relatively clean water are usually better served by a trash pump; the diaphragm pump earns its place when the water is thick, the inflow is intermittent, or dry-running is unavoidable.

Aplicaciones

  • Dewatering excavations with muddy, silt-laden seepage
  • Pumping sludge and slurry from pits, ponds, and vaults
  • Keeping footings and trench bottoms dry during slow inflow
  • Draining water with leaves, sand, or small debris
  • Standby seepage control where the pump may run dry for stretches

Seguridad y operación

  • Secure suction and discharge hoses; the pulsing flow makes unsecured lines walk and whip.
  • Ventilate engine exhaust away from trenches and confined work areas.
  • Shut down and relieve pressure before clearing a blocked valve or hose.
  • Wear eye protection when opening chambers that may hold pressurized sludge.

Normas y certificaciones

OSHA · 29 CFR 1926.651(h)
Water accumulation in excavations must be controlled before and during entry; diaphragm pumps are a common compliance tool.
OSHA · 29 CFR 1926 Subpart P
Trench dewatering equipment placement must not undermine protective systems or spoil-pile setbacks.
EPA · NPDES / Construction General Permit
Sediment-laden discharge generally requires filtration or settling before release.

Preguntas frecuentes

Can a diaphragm pump run dry?
Yes. With no impeller or mechanical seal cooled by the pumped water, dry running does not damage the pump. This makes it the default for seepage that comes and goes.
Why is flow lower than a trash pump of the same size?
A diaphragm pump moves a fixed volume per stroke, so output is modest but consistent. Trash pumps move far more clear water but need steady flow to work efficiently.
What size handles typical trench seepage?
The 2 in and 3 in sizes cover most trench and footing seepage. Larger cataloged sizes exist for high-volume sludge transfer duties.

Comparar modelos populares

Buscar por especificación →

Normalizado a las mismas unidades. Un guion significa que el valor no fue publicado.

ModeloCaudalAltura manométrica máxPotencia del motor
Grundfos UPS2 Series 34 gpm41 ft (12.5 m)-
Grundfos UPS4 GO 25-65 130 17 gpm21.3 ft (6.5 m)-
Grundfos UPS 15-50N 14 gpm16.4 ft (5.0 m)-
Imer Step-Up 120 4 gpm-8 hp
Imer Prestige 300 14 gpm-24 hp
Imer Booster 20 3 gpm-28 hp

Equipos relacionados

Explorar por fabricante

Fuentes

Cada especificación se verifica con los datos publicados por el fabricante, con la fuente enlazada como referencia.

Todos los modelos

79 modelos · Página 1 de 2 · Cada especificación citada a la fuente

Dragon Products DP4000Q/Dual Fuel
Dragon Products · Mobile Frac Pump
→
Grundfos UPS2 Series
Grundfos · Circulator Pump
41 ft (12.5 m)
34 gpm
→
Dragon Products E‑Frac
Dragon Products · Mobile Frac Pump
→
Grundfos MAGNA3 Series
Grundfos · Variable Speed Circulator Pump
→
Imer Gerris 800
Imer · Piston Pump
13 hp
→
Grundfos ALPHA1 B Series
Grundfos · Circulator Pump
→
Grundfos CMB/CMB-SP Series
Grundfos · Domestic Water Booster System
→
Imer Booster 20
Imer · Piston Pump
3 gpm
28 hp
→
Imer Koine Dual
Imer · Continuous Mixer Pump
140 gpm
→
Cornell 2415MX
Cornell · Hybrid Pump
640 gpm
→
Cornell 3419MX
Cornell · Hybrid Pump
860 gpm
→
Gorman-Rupp 7x10 Above-Ground Pressure Booster Stations
Gorman-Rupp · Above-Ground Pressure Booster Station
1,300 gpm
→
Imer Koine 3.1
Imer · Continuous Mixer Pump
→
Imer Prestige 300
Imer Prestige 300
Imer · Rotor/Stator Pump
14 gpm
24 hp
→
Thermal Care PT2800
Thermal Care · Pump Reservoir System
2,775 gpm
→
Thermal Care PTS275
Thermal Care · Small Pump Reservoir System
265 gpm
→
Imer Mighty Small 50
Imer · Rotor/Stator Pump
2 gpm
→
Gorman-Rupp HSK Series (SludgeKat )
Gorman-Rupp · self-priming, positive displacement, hydraulic piston pump
226 gpm
→
Imer Step-Up 120
Imer · Rotor/Stator Pump
4 gpm
8 hp
→
Cornell 2CB
Cornell · Refrigeration Pump
200 gpm
→
Cornell 3CB
Cornell · Refrigeration Pump
700 gpm
→
Cornell 4CB
Cornell · Refrigeration Pump
1,250 gpm
→
Griffin HP125-3000
Griffin · Reciprocating Hydrostatic Test Pump
22 gpm
→
Griffin HP165-3000
Griffin · Reciprocating Hydrostatic Test Pump
28 gpm
→
Griffin HP28-5000
Griffin · Reciprocating Hydrostatic Test Pump
4 gpm
→
Griffin HP33-5000
Griffin · Reciprocating Hydrostatic Test Pump
7 gpm
→
Griffin HP400-3000
Griffin · Reciprocating Hydrostatic Test Pump
81 gpm
→
Griffin MAC 24
Griffin · Reciprocating Hydrostatic Test Pump
→
Griffin V Slot Strainer
Griffin V Slot Strainer
Griffin · Strainer
→
Ironton 50098
Ironton · Transfer Pump
46 ft (14.0 m)
5 gpm
→
Satellite Industries Brick Pump House
Satellite Industries · Modular Pump Unit
→
Gorman-Rupp 6x6 Above-Ground Pressure Booster Stations
Gorman-Rupp · Pressure Booster Station
1,300 gpm
→
Griffin HTU-350
Griffin · Combo Fill/Test Pump
600 gpm
→
Griffin HTU-500
Griffin · Combo Fill/Test Pump
600 gpm
→
California Air Tools SP-9421-22060
California Air Tools · Pump/Motor
→
Griffin Dewatering HP125-3000
Griffin Dewatering · Reciprocating Pump
→
Griffin Dewatering HP165-3000
Griffin Dewatering · Reciprocating Pump
→
Griffin Dewatering HP28-5000
Griffin Dewatering · Reciprocating Pump
→
Griffin Dewatering HP33-5000
Griffin Dewatering · Reciprocating Pump
→
Griffin Dewatering HP400-3000
Griffin Dewatering · Reciprocating Pump
→
Griffin Dewatering V Slot Strainer
Griffin Dewatering · Strainer
→
Griffin M06-500
Griffin · Reciprocating Hydrostatic Test Pump
→
Griffin MAC 26-6000
Griffin · Reciprocating Hydrostatic Test Pump
→
Grundfos UPS 15-50N
Grundfos · Circulator Pump
16.4 ft (5.0 m)
14 gpm
→
Grundfos UPS4 GO 25-65 130
Grundfos · Circulator Pump
21.3 ft (6.5 m)
17 gpm
→
Thompson Pump 2D
Thompson Pump · Diaphragm Pump
41 ft (12.5 m)
80 gpm
→
Thompson Pump 3D
Thompson Pump · Diaphragm Pump
50 ft (15.2 m)
88 gpm
→
Thompson Pump 4D
Thompson Pump · Diaphragm Pump
50 ft (15.2 m)
140 gpm
→
Página 1 de 2 Sig. →