Ir al contenido
Catálogo
← Submersible Pump
CAT CLASS: HQ-10789

Up to 2 in Submersible Pump

Up to 2 in submersible pumps are the smallest class in the submersible ladder, designed to drop into confined spaces like sumps, manholes, and flooded elevator pits and operate on standard 120V power. This size class handles light-duty dewatering in tight quarters where portability and ease of deployment matter more than high flow rates. For larger volumes or higher head requirements, the 2-4 in submersible pump class offers greater capacity.

251
Modelos
23
Marcas
Submersible Pump

Cat classes

Elija una clase de tamaño — la capacidad y el alcance varían en la gama.

Especificaciones clave

EspecificaciónRango típicoQué significa
Discharge SizeUp to 2 in NPTSmall port diameter limits flow but allows flexible hose routing in confined spaces.
Power Supply120V, 15A standard outletPlugs directly into building power without dedicated circuits or generators.
Solids Handling1/4 in to 3/8 inStrainer or impeller design passes small debris but requires pre-screening for sandy or silty water.

Cómo elegir

This size class is the right choice for low-volume dewatering in small, confined spaces where portability and standard electrical service are paramount—think basement sumps, shallow elevator pits, or utility vaults. The pump's compact footprint and light weight make it easy to carry and position by hand. When flow rates exceed a few dozen gallons per minute, or when head requirements rise above 20–25 feet, the 2-4 in submersible pump class becomes the more effective tool, offering larger impellers and motor horsepower to match the demand.

Lo que maneja este tamaño

  • Draining a flooded residential basement sump after a storm
  • Removing standing water from a shallow elevator pit during building maintenance
  • Dewatering a utility manhole for inspection or minor repairs
  • Clearing accumulated water from a crawl space or mechanical room
  • Pumping out a small excavation or trench where flow is under 50 GPM

Seguridad y operación

  • Ensure pump is fully submerged or cooled per manufacturer specifications; some models rely on water for motor cooling
  • Verify electrical connections are protected from water intrusion; use GFCI-protected circuits in all wet applications
  • Check solids-handling capacity and install strainer or filter if sediment or debris exceeds pump rating
  • Secure discharge hose to prevent whipping or dislodgement under pressure

Transporte y logística

  • Carried by hand; most units weigh under 30 pounds and fit in a van or pickup bed
  • No trailer required; discharge hose and power cord store with the pump in a tool bag or bucket

Alimentación

  • Standard 120V, 15A outlet; no generator or dedicated circuit needed in most buildings
  • Cord length typically 25–50 feet; extension cords must be rated for outdoor/wet use and match amperage
  • GFCI protection required when operating in wet environments

Preguntas frecuentes

What flow rate does an up to 2 in submersible pump deliver?
Flow depends on head and motor size, but this class typically delivers 20–60 GPM at low head. Performance drops quickly as vertical lift increases, so check the pump curve for the specific application.
Can this size handle dirty water or construction sites?
Only if solids are small and infrequent. Most models in this class pass particles up to 3/8 in, but sand, silt, and fibrous debris can clog impellers or damage seals. For heavily contaminated water, a trash pump or larger submersible is more appropriate.
When should a contractor move up to the 2-4 in size class?
When flow requirements exceed 60 GPM, head exceeds 25 feet, or the job involves continuous pumping over several hours. The larger class offers more robust motors and impellers for sustained duty cycles.

Equipos relacionados

Explorar por fabricante

Fuentes

Cada especificación se verifica con los datos publicados por el fabricante, con la fuente enlazada como referencia.

Up to 2 in Submersible Pump

1 modelos · Cada especificación citada a la fuente