Aller au contenu
Catalogue
← Dewatering Pumps

Trash Pump

A trash pump is a portable, gasoline-powered centrifugal pump designed to handle water containing solids, debris, and suspended material. These rugged dewatering pumps feature larger impeller clearances and reinforced components to pass solids without clogging, making them essential for construction site dewatering, flood response, and excavation management. The equipment class spans from compact 2-inch models for trenches to large 8-inch and larger units for municipal-scale operations.

255
Modèles
2–8 in (5.1–20.3 cm)
Discharge Size
22
Marques
Trash Pump

Cat classes

Choisissez une classe de taille — la capacité et la portée varient selon la gamme.

Fonctionnement

A trash pump uses a centrifugal impeller driven by a gasoline engine to create flow and pressure. The impeller design features wider vane spacing and larger clearances than standard water pumps, allowing passage of solids ranging from small debris to rocks several inches in diameter, depending on pump size. Self-priming mechanisms or manual priming allow the pump to draw water from several feet below the pump centerline. The pump draws water and debris through a suction hose, accelerates it through the impeller chamber, and discharges it through a hose or pipe to a disposal point. Wear plates and hardened impellers resist abrasion from sand and grit. Most units operate as open-impeller or semi-open designs to prevent clogging, with some incorporating debris screens or strainers at the inlet.

Types et variantes

Standard Trash Pump
General-purpose units handling solids up to approximately 1 inch diameter, suitable for typical construction dewatering with mud, sand, and small debris.
Semi-Trash Pump
Intermediate design between clean water and full trash capability, passing smaller solids while maintaining higher head and flow efficiency.
High-Head Trash Pump
Specialized pumps optimized for greater discharge heights or long horizontal runs, sacrificing some solids-handling capacity for increased pressure.
Diaphragm Trash Pump
Positive-displacement design using flexible diaphragm(s) to handle highly viscous slurries, sludge, and larger solids than centrifugal types.
Submersible Trash Pump
Electric-powered units designed to operate fully submerged, often used in deeper sumps or continuous applications where engine exhaust is problematic.

Spécifications clés

SpécificationPlage typiqueSignification
Discharge Size2–8 in (5.1–20.3 cm)Nominal diameter of the discharge connection; determines flow capacity and the maximum size of solids that can pass through the pump.
Max Head10–246 ft (3.0–75.0 m)Maximum vertical lift and pressure capability; indicates how high or how far the pump can move water against resistance.
Engine Power3.5–99.9 hpGasoline engine horsepower driving the pump; larger engines support higher flow rates and greater head capacity.
Operating Weight97.0–5,190 lb (44–2,354 kg)Total weight of the unit; affects portability, with smaller pumps carried by one person and larger units requiring lifting equipment or trailers.
Fuel Tank Capacity1.2–6.1 LOnboard fuel storage determining runtime between refueling; larger tanks support extended unattended operation.

Comment l'industrie le dimensionne

The rental industry sizes trash pumps by discharge diameter in inches, ranging from compact 2-inch models through 3-inch and 4-inch workhorses to large 6-inch, 8-inch, and larger municipal units. A 2-inch pump typically delivers approximately 150 gallons per minute for footings and trenches and can be carried by one person. The 3-inch and 4-inch sizes dominate general construction work, moving 300 and 500 gpm respectively. Larger 6-inch and 8-inch pumps, delivering 1,500 gpm or more, serve cofferdams, flood control, and sewer bypass applications. Flow rate, head capacity, and solids-handling capability all scale with discharge size, making diameter the primary sizing criterion.

Applications

  • Dewatering excavations, footings, trenches, and building foundations during construction
  • Removing standing water from flooded basements, parking structures, and work areas
  • Managing groundwater inflow in utility line installation and repair projects
  • Emergency flood response and stormwater management for municipalities and property owners
  • Sewer and water main bypass pumping during repair or replacement operations
  • Coffer dam and caisson dewatering for bridge and marine construction

Sécurité et opération

  • Position gasoline engines in well-ventilated areas with exhaust directed away from workers and confined spaces to prevent carbon monoxide accumulation
  • Inspect suction and discharge connections for secure attachment before starting; unsecured hoses under pressure can whip violently and cause injury
  • Maintain stable footing around pumps and hoses on wet, muddy jobsites; pressurized water discharge creates slippery conditions
  • Monitor fuel levels and refuel only when the engine is off and cool; gasoline vapors near hot engine components present fire hazards
  • Protect electrical equipment and connections from water contact when operating pumps near excavations or in wet environments

Normes et certifications

OSHA · 29 CFR 1926.152
Flammable liquids standard governing gasoline storage, handling, and refueling procedures on construction sites.
EPA · Tier 4
Emission standards for off-road engines; newer trash pump engines comply with progressively stricter tiers to reduce exhaust pollutants.
ANSI/HI · ANSI/HI 9.6.7
Hydraulic Institute standard for pump installation, operation, and maintenance covering centrifugal and rotary pumps.
NFPA · NFPA 70
National Electrical Code provisions apply when trash pumps are used near electrical installations or with electric-start systems.

Questions fréquentes

What is the difference between a trash pump and a semi-trash pump?
A trash pump features larger impeller clearances and reinforced construction to pass solids up to approximately 1 inch or larger, while a semi-trash pump has tighter clearances optimized for smaller debris and offers higher head and efficiency. Trash pumps prioritize solids handling; semi-trash pumps balance debris capability with performance.
How is trash pump size related to flow rate?
Discharge diameter in inches determines approximate flow capacity: 2-inch pumps typically deliver around 150 gpm, 3-inch models around 300 gpm, 4-inch around 500 gpm, and 6-inch around 1,500 gpm. Actual flow varies with head pressure, engine power, and specific pump design, but diameter serves as the primary flow indicator.
Can a trash pump run dry or does it require priming?
Most trash pumps are self-priming but require the pump chamber to be filled with water initially to create suction. Running a centrifugal trash pump dry, even briefly, can damage seals and overheat components. Diaphragm-type trash pumps tolerate dry running better but still benefit from wet priming for efficiency.
What determines the maximum size of solids a trash pump can handle?
Impeller design, vane spacing, and inlet screen or strainer size determine solids-handling capacity. As a general rule, centrifugal trash pumps can pass spherical solids up to approximately 25–30% of the discharge diameter, meaning a 4-inch pump handles solids around 1 to 1.25 inches, though manufacturer specifications vary.

Comparer les modèles populaires

Chercher par spécification →

Normalisé aux mêmes unités. Un tiret signifie que la valeur n'a pas été publiée.

ModèleDébitHauteur manométrique maxPuissance moteur
Multiquip MQ600HTB 1,600 gpm150 ft (45.7 m)100 hp
Multiquip MQ600H 1,600 gpm150 ft (45.7 m)-
Multiquip MQ600HTP 1,600 gpm150 ft (45.7 m)100 hp
Multiquip QP2TH 211 gpm98.4 ft (30.0 m)5 hp
Multiquip QP4TH 555 gpm92 ft (28.0 m)11 hp
Multiquip QP3TH 396 gpm95 ft (29.0 m)-

Équipements connexes

Parcourir par fabricant

Sources

Chaque spécification est vérifiée par rapport aux données publiées par le fabricant, avec la source liée pour référence.

Tous les modèles

255 modèles · Page 4 sur 6 · Chaque spécification citée à la source

Multiquip QP3TZ
Multiquip
Multiquip QP40TE
Multiquip
Multiquip QP40TH
Multiquip
Multiquip QP4TE
Multiquip
Multiquip QP4TZ
Multiquip
Multiquip TLW-300SS
Multiquip
Pentair Myers MPN Series Shallow Well Jet Pumps
Pentair Myers · Jet Pump
25 ft (7.6 m)
18 gpm
Pentair Myers QD Series Quick Draw Shallow Well Jet Pumps
Pentair Myers · Jet Pump
25 ft (7.6 m)
27 gpm
Pentair Myers MFN Series Shallow Well Jet Pumps
Pentair Myers · Jet Pump
14 gpm
Tsurumi TE2-25HA
Tsurumi · Engine-Driven Centrifugal Pump
Gorman-Rupp 12D1-1B30E FT4 S/G
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D-11
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D-13
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D-1B20 FT4
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D-6LD260
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D-6LD325
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D-CH6
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D-GX160
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D-L48AE
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D-L48EE S/G
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D-L48EE S/G /S1
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D1-1B20
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D1-1B20 FT4
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D1-GX160
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D1-L48EE
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12A1-11
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12B2-530RT
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12B2-AB1
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D-1B20
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D-1B30 FT4
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D-1B30E FT4 S/G
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D-GX140
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D1-1B30
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D1-1B30 FT4
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D13-13
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12E1-1B20
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12E1-GX160
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12A1-GX140
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12A1-GX160
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 12D-500RT
Gorman-Rupp · Self Priming Pump
Tsurumi EPT3-50HA
Tsurumi · Engine-Driven Trash Pump
Tsurumi TE3-50HA
Tsurumi · Engine-Driven Centrifugal Pump
Gorman-Rupp 13A2-AENLD S/G
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 13A2-AENLD S/G LPG
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 13A2-M12
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 13A2-M12 S/G
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 13A2-ST1 S/G
Gorman-Rupp · Self Priming Pump
Gorman-Rupp 13A52-CH13
Gorman-Rupp · Self Priming Pump
← Préc. Page 4 sur 6 Suiv. →