Ir al contenido
Catálogo
← Chillers

Air-Cooled Chiller

An air-cooled chiller is a self-contained refrigeration machine that produces chilled water by rejecting heat to ambient air rather than to a cooling tower or water loop. These units are widely deployed in the industry for temporary cooling, emergency backup during equipment failures, seasonal peak load support, and process cooling applications where water-cooled infrastructure is unavailable or impractical.

109
Modelos
10–500+ tons
Cooling Capacity
12
Marcas
Air-Cooled Chiller

Cómo funciona

The chiller circulates a refrigerant through a vapor-compression cycle: a compressor raises refrigerant pressure and temperature, the hot gas flows through an air-cooled condenser where fans blow ambient air across finned coils to reject heat, the refrigerant then passes through an expansion valve to drop pressure, and finally the cold refrigerant absorbs heat from process water in an evaporator. The chilled water loop circulates through connected equipment or air handlers, returning warmer water to the chiller to be cooled again. Air-cooled chillers require only electrical power and process water connections, eliminating the need for cooling towers, condenser water pumps, and water treatment systems. Portable units typically ship as complete packages with integrated controls, pumps, and refrigerant charge, ready to connect to temporary distribution piping or existing building infrastructure.

Tipos y variantes

Scroll Compressor Chillers
Use scroll compressors for quiet, reliable operation; common in small to mid-size units up to about 60 tons.
Screw Compressor Chillers
Employ rotary screw compressors for higher capacities and continuous-duty industrial applications, typical above 60 tons.
Skid-Mounted Portables
Factory-assembled on a steel skid or frame with lifting points and forklift pockets for easy jobsite placement.
Trailer-Mounted Chillers
Built onto road-towable trailers for rapid deployment and relocation; often used for emergency response or events.
Low-Ambient Chillers
Equipped with head-pressure control and special controls to maintain operation in cold outdoor conditions.
High-Efficiency Chillers
Feature variable-speed drives, advanced controls, and optimized heat exchangers to reduce energy consumption.

Especificaciones clave

EspecificaciónRango típicoQué significa
Cooling Capacity10–500+ tonsThe refrigeration output, sized to match building or process heat load; the primary sizing parameter.
Airflow1,110–4,000 cfmVolume of ambient air moved across the condenser coils to reject heat; determines clearance and noise considerations.
Chilled Water Temperature40–50°F leavingThe supply water temperature delivered to the process or air handlers; field-adjustable within design limits.
Power Supply208–480V, 3-phaseElectrical requirements vary with chiller size; larger units typically require higher voltages and dedicated feeds.
Refrigerant TypeR-410A, R-134a, R-513AThe working fluid in the refrigeration cycle; must comply with environmental regulations and efficiency standards.

Cómo la industria lo dimensiona

The industry sizes air-cooled chillers by cooling capacity in tons of refrigeration (one ton equals 12,000 Btu/hr). Units up to 25 tons provide self-contained chilled water for a tent, a small process loop, or one air handler. The 25–60 ton range handles a floor of a building or a mid-size process load—the everyday chiller in the fleet. Chillers from 60–150 tons cover a whole building or a production line while the plant chiller is down. Large units from 150–350 tons handle large temporary cooling—hospital, data hall, or turnaround; these ship on a lowboy. Plant-scale cooling above 350 tons typically involves several units paralleled into one loop.

Aplicaciones

  • Emergency replacement cooling when permanent building chillers fail or undergo maintenance
  • Temporary HVAC for construction sites, temporary structures, tents, and special events
  • Supplemental cooling during peak summer loads or building expansions before permanent equipment is installed
  • Industrial process cooling for manufacturing, plastics processing, and chemical production
  • Data center and server room environmental control for IT equipment protection
  • Medical and pharmaceutical facility temperature control during renovations or equipment upgrades

Seguridad y operación

  • Maintain manufacturer-specified clearances around air intake and discharge to prevent recirculation of warm exhaust air and ensure adequate condenser performance
  • Verify electrical connections match chiller nameplate voltage and phase; ensure proper grounding and overcurrent protection per NEC requirements
  • Monitor refrigerant charge and inspect for leaks regularly; refrigerants are regulated substances requiring certified technicians for service
  • Protect water piping from freezing during shutdown in cold climates; drain or use glycol solutions as appropriate
  • Ensure adequate structural support for skid-mounted or trailer units, especially on rooftops or elevated platforms where weight loads must be verified

Normas y certificaciones

AHRI · Standard 550/590
Performance rating standards for water-chilling and heat-pump water-heating packages using the vapor-compression cycle
ASHRAE · Standard 15
Safety standards for refrigeration systems, covering design, construction, installation, and operation of mechanical refrigeration
EPA · Section 608/609
Federal regulations governing refrigerant handling, recovery, recycling, and technician certification to protect stratospheric ozone

Preguntas frecuentes

How does an air-cooled chiller differ from a water-cooled chiller?
Air-cooled chillers reject heat directly to ambient air using fans and finned coils, while water-cooled chillers require a separate cooling tower and condenser water loop. Air-cooled units are self-contained and simpler to deploy, making them the standard choice for temporary applications, though they are less efficient in hot climates and consume more energy than water-cooled equivalents.
What factors affect the capacity of an air-cooled chiller?
Capacity decreases as ambient air temperature rises, since the temperature difference between refrigerant and air diminishes. Altitude, condenser coil cleanliness, and airflow restrictions also impact performance. Most manufacturers provide capacity correction factors or performance curves to account for site conditions when sizing equipment.
Can air-cooled chillers operate in cold weather?
Standard chillers may experience operational issues below approximately 50°F ambient due to low refrigerant head pressure. Low-ambient chillers include head-pressure control features such as variable-speed condenser fans, dampers, or refrigerant flooding controls to maintain stable operation down to 0°F or lower, enabling year-round or cold-climate use.
What is the typical lead time for chiller deployment?
Depending on fleet availability and transportation logistics, chillers can often be delivered and operational within 24–72 hours for emergency situations. Larger units or specialized configurations may require advance planning for permitting, rigging, electrical work, and integration with existing building systems.

Explorar por fabricante

Fuentes

Cada especificación se verifica con los datos publicados por el fabricante, con la fuente enlazada como referencia.

Todos los modelos

109 modelos · Página 2 de 3 · Cada especificación citada a la fuente

Johnson Controls YORK YCIV Air-Cooled VSD Screw Chiller
Johnson Controls · Air-Cooled Chiller
Johnson Controls YORK YK Centrifugal Water-Cooled Chiller
Johnson Controls · Water-Cooled Chiller
Johnson Controls YORK YLAA Air-Cooled Scroll Chiller
Johnson Controls · Air-Cooled Chiller
Mcquay Navigator WWV
Mcquay · Water-Cooled Screw Chiller
Mcquay Pathfinder AWV
Mcquay · Air-Cooled Screw Compressor Chiller
Americool TM 127-1.0-3.0
Americool · Thermoelectric Module (Single-Stage)
Americool TM 127-1.0-4.0
Americool · Thermoelectric Module (Single-Stage)
Americool TM 127-1.4-4.0
Americool · Thermoelectric Module (Single-Stage)
Americool TM 127-1.4-6.0
Americool · Thermoelectric Module (Single-Stage)
Americool TM 127-1.4-8.5
Americool · Thermoelectric Module (Single-Stage)
Americool TM 31-1.0-4.0
Americool · Thermoelectric Module (Single-Stage)
Americool TM 31-1.0-6.0
Americool · Thermoelectric Module (Single-Stage)
Americool TM 31-1.4-8.5
Americool · Thermoelectric Module (Single-Stage)
Americool TM 71-1.0-3.0
Americool · Thermoelectric Module (Single-Stage)
Americool TM 71-1.0-4.0
Americool · Thermoelectric Module (Single-Stage)
Americool TM 71-1.0-6.0
Americool · Thermoelectric Module (Single-Stage)
Americool TM 71-1.4-6.0
Americool · Thermoelectric Module (Single-Stage)
Americool TM 71-1.4-8.5
Americool · Thermoelectric Module (Single-Stage)
Johnson Controls YORK YCWL Scroll Water-Cooled Chiller
Johnson Controls · Water-Cooled Chiller
Johnson Controls YORK YMC2 Magnetic Drive Water-Cooled Centrifugal Chiller
Johnson Controls · Water-Cooled Chiller
Mcquay Magnitude WMT
Mcquay · Water-Cooled Centrifugal Chiller
Mcquay Trailblazer AGZ-F
Mcquay · Air-Cooled Scroll Chiller
Johnson Controls YORK YDAM Air-Cooled Magnetic Bearing Centrifugal Chiller
Johnson Controls · Air-Cooled Chiller
Johnson Controls YORK YHAU-C Single Effect Steam Absorption Chiller
Johnson Controls · Absorption Chiller
Johnson Controls YORK YHAU-CG Direct Fired Absorption Chiller
Johnson Controls · Absorption Chiller
Mcquay Magnitude WMC
Mcquay · Water-Cooled Centrifugal Chiller
Mcquay Magnitude WME
Mcquay · Water-Cooled Centrifugal Chiller
Mcquay Navigator TWV
Mcquay · Water-Cooled Screw Heat Pump Chiller
Mcquay Trailblazer EWYQ
Mcquay · Air-Cooled Heat Pump Chiller
Johnson Controls YORK YHAU-CXR Direct Fired Absorption Chiller/Heater
Johnson Controls · Absorption Chiller
Aggreko 10 Ton Air-Cooled Chiller
Aggreko · Air-Cooled Chiller
Aggreko 100 Ton Air-Cooled Chiller
Aggreko · Air-Cooled Chiller
Aggreko 1000 Ton Water-Cooled Chiller
Aggreko · Water-Cooled Chiller
Aggreko 200 Ton Air-Cooled Chiller
Aggreko · Air-Cooled Chiller
Aggreko 30 Ton Air-Cooled Chiller
Aggreko · Air-Cooled Chiller
Aggreko 400 Ton Air-Cooled Chiller
Aggreko · Air-Cooled Chiller
Aggreko 420 Ton Air-Cooled Chiller
Aggreko · Air-Cooled Chiller
Aggreko 500 Ton Water-Cooled Chiller
Aggreko · Water-Cooled Chiller
Aggreko 60 Ton Air-Cooled Chiller
Aggreko · Air-Cooled Chiller
Aggreko Ultra Low Temp Chiller
Aggreko · Ultra Low Temperature Chiller
Carrier AquaEdge 17DA
Carrier · Chiller
Carrier AquaEdge 19DV
Carrier · Chiller
Carrier AquaEdge 19MV
Carrier · Chiller
Carrier AquaEdge 19XR
Carrier · Chiller
Carrier AquaEdge 23XRV
Carrier · Chiller
Carrier AquaForce 23XQ
Carrier · Chiller
Carrier AquaForce 23XW
Carrier · Chiller
Carrier AquaForce 30HX
Carrier · Chiller
← Ant. Página 2 de 3 Sig. →