← Towable Diesel Generator
CAT CLASS: HQ-10736

25-60 kW Towable Diesel Generator

The 25-60 kW towable diesel generator occupies the mid-range of the towable generator ladder, sized for trailer complexes, multiple pumps, or small hoists. This class bridges the gap between light single-load units and larger multi-zone or high-demand equipment. With 8 models from manufacturers including Echo, Magnum, and IHI, this size class delivers 32.5-59.0 kVA in a road-towable package.

114
Modelos
24
Marcas
Towable Diesel Generator

Cat classes

Elija una clase de tamaño: la capacidad y el alcance varían en la gama.

Especificaciones clave

EspecificaciónRango típicoQué significa
Power output32.5-59.0 kVAContinuous power available for connected loads, sufficient for several medium-draw devices or one high-demand piece of equipment.
Fuel capacity51.5-106.0 galOnboard diesel storage determining run time between refueling, typically supporting 12-24 hours at half load.
Sizing basis25-60 kWNameplate kilowatt rating used by the industry to classify and compare units within this band.

Cómo elegir

This size class suits operations requiring 30-60 kVA to power a small trailer office complex, run two or three dewatering pumps simultaneously, or supply a small hoist and ancillary lighting. For single light towers, small welders, or one dewatering pump, the Up to 25 kW Towable Diesel Generator is more efficient and easier to position. When powering multiple trailers with HVAC, larger temporary facilities, or high-draw equipment like large compressors or concrete batch plants, the 60-150 kW Towable Diesel Generator becomes necessary. The decision hinges on total connected load and whether the site requires power distribution to multiple zones or can operate from a single feed point.

Lo que maneja este tamaño

  • Powering a small office trailer complex with lighting, computers, and space heaters
  • Running two to three 6-inch dewatering pumps on a construction site
  • Supplying a small material hoist and perimeter lighting on a mid-rise project
  • Supporting temporary power for a remote cell tower installation with backup redundancy
  • Energizing a small batch plant mixer and conveyor system
  • Providing event power for food vendors and stage lighting at a community festival

Seguridad y operación

  • Generators must be grounded per NEC Article 250 and positioned to direct exhaust away from occupied structures and air intakes
  • Fuel storage and refueling operations follow NFPA 30 and local fire codes; hot refueling is prohibited
  • Soundproofed enclosures reduce noise but require adequate ventilation clearance to prevent overheating
  • Load bank testing and transfer switch coordination are essential when integrating with existing electrical systems or backup configurations

Transporte y logística

  • Towable behind a 3/4-ton or 1-ton pickup truck via standard 2-inch ball or pintle hitch, requiring a vehicle with appropriate towing capacity for combined generator and trailer weight
  • Road-legal running lights, brakes, and DOT-compliant trailer ensure highway transport between job sites
  • Compact footprint allows positioning in staging areas or along site perimeters without crane or forklift assistance

Alimentación

  • Onboard diesel fuel tank with 51.5-106.0 gallon capacity; refueling intervals depend on load profile, typically 12-24 hours at 50% capacity
  • Output via panel-mounted receptacles or cam-lock connectors, often including 120/240V single-phase and 208V or 480V three-phase options
  • Automatic voltage regulation and circuit protection built into the control panel for stable power delivery

Preguntas frecuentes

How does kVA relate to the kW rating in this size class?
kVA (apparent power) is typically 10-15% higher than kW (real power) depending on the power factor of connected loads. A 50 kW generator may produce 55-60 kVA; inductive loads like motors reduce the usable kW from a given kVA rating.
What distinguishes this size from the 60-150 kW class?
The 25-60 kW class typically serves single-zone or limited multi-load applications, while the 60-150 kW class supports larger distribution panels, multiple simultaneous high-draw loads, or facilities requiring redundant capacity. Fuel tank size and run time also increase significantly in the larger class.
Can this size run continuously or only intermittently?
Industrial towable generators in this class are designed for continuous duty, with manufacturer-rated prime power output available 24/7 under proper maintenance. Standby ratings, if listed, indicate higher short-duration capacity not suitable for continuous operation.

Comparar modelos populares

Buscar por especificación →

Normalizado a las mismas unidades. Un guion significa que el valor no fue publicado.

ModeloPotencia de salidaCapacidad de combustible
Echo DGK20FS 33 hp51.5 gal
Echo DGK25F 33 hp51.5 gal
Echo DGK36FS 59 hp79.3 gal
Echo DGK45F 59 hp79.3 gal
Magnum MMG35FHD -106.0 gal
Magnum MMG45FHK -106.0 gal