The 60-150 kW towable diesel generator provides whole-site power for construction projects, running hoists, office trailers, task lighting, and tool loads concurrently. This mid-range size sits between the 25-60 kW band for lighter loads and the 150-300 kW band for large commercial sites. Output ranges from 77.5 to 180.0 kVA, with fuel capacity from 165 to 342 gallons.

114
Modelos
24
Marcas
Towable Diesel Generator

Cat classes

Elija una clase de tamaño: la capacidad y el alcance varían en la gama.

Especificaciones clave

EspecificaciónRango típicoQué significa
Power output77.5-180 kVAContinuous capacity for combined site loads including mechanical equipment and site offices
Fuel capacity165-342 gallonsExtended runtime between refueling, often 24-48 hours under typical site loads
Power rating band60-150 kWPrime power range defining this class; actual output depends on load factor and altitude

Cómo elegir

This size suits projects where multiple trades operate simultaneously from a single generator: framing crews with lifts, temporary HVAC in trailers, string lighting across the site, and a mix of corded tools. The 25-60 kW Towable Diesel Generator is appropriate when loads are limited to a single trade or smaller tool packages without elevator or HVAC demand. Step up to the 150-300 kW Towable Diesel Generator when powering multiple large hoists, concrete pumps, or when phased commercial sites require redundancy and the ability to section distribution panels.

Lo que maneja este tamaño

  • Mid-rise residential construction powering personnel hoist, temporary heat, and multiple floors of tools
  • Retail or office build-out with HVAC startup loads, compressors, and temporary tenant lighting
  • Bridge or roadway project running batch plant conveyors, field office trailers, and area lighting
  • Industrial maintenance outage where backup power supports welding stations, cranes, and safety systems
  • Event infrastructure providing distributed power to stages, vendors, and support facilities
  • Municipal job site running dewatering pumps, excavation equipment, and contractor trailers simultaneously

Seguridad y operación

  • Exhaust positioning and carbon monoxide hazards require clearance from occupied trailers and air intakes
  • Lockout/tagout procedures necessary when multiple trades connect or disconnect from distribution panel
  • Ground fault protection and proper bonding to site ground per NEC Article 250
  • Noise levels typically 65-75 dBA at 23 feet; local ordinances may govern permissible hours and sound barriers

Transporte y logística

  • Towable trailer chassis with DOT-compliant lighting and brakes; requires Class 3 or heavier tow vehicle
  • Typical trailer weight with full fuel exceeds 10,000 lbs; tow vehicle GCWR and hitch rating must be verified
  • Width and overhang require attention to clearances during backing and turning on congested sites

Alimentación

  • Diesel fuel supply; consumption varies with load but typically 5-12 gallons per hour at 75% capacity
  • Distribution via main breaker panel with multiple branch circuits; common configurations include 480V three-phase and 240/120V single-phase outputs
  • Refueling access required; many sites schedule bulk delivery or use slip tanks depending on runtime needs

Preguntas frecuentes

How does this size compare to utility temporary service for a construction site?
This generator class provides similar capacity to a 200-400 amp utility temporary service but offers independence from utility lead times, trenching costs, and deposit requirements. It is common on sites where utility installation lags the construction schedule or where location makes grid connection impractical.
What distinguishes the upper and lower ends of the 60-150 kW range?
Units near 60 kW handle typical light-commercial or residential high-rise trade loads, while models approaching 150 kW support heavier industrial equipment, larger HVAC startup currents, or allow headroom for load growth as the project phases progress.
Can this size start large motors or handle inrush current from compressors?
Units in this class are typically rated for motor starting with inrush currents 3-6 times running amperage, but the specific starting kVA must be calculated against the generator's short-term overload capacity and any soft-start or VFD controls on the equipment.

Comparar modelos populares

Buscar por especificación →

Normalizado a las mismas unidades. Un guion significa que el valor no fue publicado.

ModeloPotencia de salidaCapacidad de combustible
Generac MDG150DF4 120.0 kVA-
Generac MGG210N2 185.0 kVA-
Generac MDG175DF4 140.0 kVA-
Atlas Copco QAS 125 JD -166.0 gal
Chicago Pneumatic CPG 125 T4F -166.0 gal
Chicago Pneumatic CPG 150 T4F -335.0 gal

Equipos relacionados

Explorar por fabricante

Fuentes

Cada especificación se verifica con los datos publicados por el fabricante, con la fuente enlazada como referencia.

60-150 kW Towable Diesel Generator

19 modelos · Cada especificación citada a la fuente

Magnum MMG75D
Magnum · Generator
165.0 gal
→
Generac MDG100DF4
Generac · Mobile Generator
80.0 kVA
→
Magnum MMG100D
Magnum · Generator
165.0 gal
→
Chicago Pneumatic CPG 125 T4F
Chicago Pneumatic · Mobile Diesel Generator
166.0 gal
→
Atlas Copco QAS 125 JD
Atlas Copco · Mobile Diesel Generator
166.0 gal
→
Cummins C100D2RE
Cummins · Towable Diesel Generator
→
Chicago Pneumatic CPG 150 T4F
Chicago Pneumatic · Mobile Diesel Generator
335.0 gal
→
Generac MDG150DF4
Generac · Mobile Generator
120.0 kVA
→
Doosan Portable Power G125WCU-3A-T4F
Doosan Portable Power · Mobile Generator
125.0 kVA
→
Generac MDG175DF4
Generac · Mobile Generator
140.0 kVA
→
Magnum MMG150
Magnum · Generator
342.0 gal
→
Doosan Portable Power G150WCU-3A-T4F
Doosan Portable Power · Mobile Generator
154.0 kVA
→
Chicago Pneumatic CPG 200 T4F
Chicago Pneumatic · Mobile Diesel Generator
335.0 gal
→
Cummins C150D2RE
Cummins · Towable Diesel Generator
169.0 kVA
→
Magnum MMG170
Magnum · Generator
342.0 gal
→
Magnum MMG235
Magnum · Generator
342.0 gal
→
Doosan Portable Power G190WCU-3A-T4F
Doosan Portable Power · Mobile Generator
181.0 kVA
→
Caterpillar Cat XQ230 Tier 4 Final
Caterpillar · Towable Diesel Generator
182.0 kVA
→
Generac MGG210N2
Generac · Mobile Generator
185.0 kVA
→