Skip to content
Heyquip Heyquip Catalog
← Portable Generator
CAT CLASS: HQ-10730

12+ kW Portable Generator

The 12+ kW portable generator is the top rung of the portable generator ladder, delivering prime power from 14 to 75 kW and standby ratings from 14.7 to 85 kW. This size backs up small service panels, powers multiple heavy tools simultaneously, or supplies baseload electricity for large work crews. Operating weights span 271 to 2,771 kg, with wheeled trailer configurations common at the upper end.

269
Models
15
Brands
Portable Generator

Cat classes

Pick a size class: capacity and reach differ across the range.

Key specifications

SpecificationTypical rangeWhat it means
Prime power14-75 kWContinuous power available for sustained loads; the upper end supports multiple high-draw tools or light commercial backup.
Standby power14.7-85 kWShort-duration peak capacity for starting inrush or temporary overloads.
Fuel capacity25-110 galExtended runtime without refueling; larger tanks support overnight or multi-shift operation.
Operating weight597–6,109 lb (271–2,771 kg)Heavier units include trailer frames, larger engines, and sound-attenuated enclosures.
Sound level61-74 dB(A)Enclosed models at the lower end meet noise ordinances for occupied areas and night work.

How to choose

The 12+ kW band suits applications backing up a small electrical panel, running multiple high-draw tools (welders, compressors, saws) concurrently, or supplying baseload power to a crew trailer or site office. For one or two moderate tools, a chop saw and lights, or a single welder, the 7-12 kW Portable Generator is lighter, more fuel-efficient, and easier to position. This top rung has no step up within the portable generator class; larger power needs move to towable or stationary generator sets outside this classification.

What this size handles

  • Emergency backup for a small office, clinic, or home service panel during outages
  • Powering a full carpentry or masonry crew with simultaneous saw, mixer, and lighting loads
  • Running multiple welders and grinders on a steel fabrication or pipeline site
  • Baseload electricity for a construction trailer, portable office, or remote field camp
  • Supporting HVAC startup loads and continuous operation during building commissioning
  • Providing redundant power for outdoor events, food service, or mobile medical units

Safety & operation

  • Position exhaust downwind and at least 3 meters from air intakes, doors, and occupied spaces to prevent carbon monoxide accumulation
  • Confirm load calculations do not exceed the prime rating; sustained overload trips protection or damages windings
  • Use a transfer switch or interlock when connecting to a building panel to prevent backfeed into utility lines
  • Inspect fuel lines, battery terminals, and coolant levels before startup; vibration and heat accelerate wear on high-hour units

Transport & logistics

  • Lighter models (under 500 kg) move on integrated wheels or lift into pickups with two operators or a hoist
  • Mid-weight units (500-1,200 kg) tow behind trucks on single-axle trailer frames with standard 2-inch ball hitches
  • Heaviest configurations (over 1,200 kg) require tandem-axle trailers and may need brake-equipped tow vehicles per local codes

Power & supply

  • Diesel fuel is standard across most models; gasoline and dual-fuel (gasoline/propane) options exist at the lower end of the band
  • Refueling intervals range from 8 to 24+ hours at half load, depending on tank size and prime rating
  • Output typically connects via twist-lock receptacles (L14-30, CS6364, CS8264) or direct hardwire to a distribution panel or transfer switch

Frequently asked

What distinguishes prime power from standby power ratings?
Prime power is the maximum continuous load the generator can supply indefinitely with routine maintenance intervals. Standby power permits short overloads (typically 1 hour in 12) and is intended for emergency backup, not constant use.
Can a 12+ kW generator start a large electric motor?
Starting inrush current typically draws 3-6 times the motor's running load. A 5 hp motor (roughly 4 kW running) may require 12-24 kW for startup; confirm the generator's standby rating and any soft-start equipment on the load.
How does sound level affect placement on jobsites?
Models rated below 70 dB(A) at 7 meters meet most municipal noise ordinances and permit closer placement to occupied structures. Units above 70 dB(A) may require setback distances of 15 meters or more, or operation restrictions during night hours.

Compare popular models

Find by spec →

Normalised to the same units. A dash means the figure was not published.

ModelPower outputFuel capacity
Allmand Maxi-Power 25 25.0 kVA52.0 gal
Multiquip DA7000SSA3 9.3 kw6.6 gal
Multiquip DCA15SPXU4F 18.3 kw28.0 gal
Wacker Neuson G25 37 kw62.6 gal
Generac MDG25IF4 20.0 kVA-
Generac MDG75DF4 60.0 kVA-

Related equipment

Browse by manufacturer

Sources

Every specification is verified against the manufacturer's published data, with the source linked for reference.

12+ kW Portable Generator

66 models · Page 1 of 2 · Every spec cited to source

Multiquip DA7000SSA3
Multiquip · Equipment
9.3 kw
12 hp
597 lb (271 kg)
→
Multiquip DCA15SPXU4F
Multiquip · Equipment
18.3 kw
25 hp
1,179 lb (535 kg)
→
Multiquip DCA-15SPX4
Multiquip
15 kW
36 hp
→
Multiquip DCA15SPX
Multiquip
15 kW
36 hp
→
Multiquip DCA15SPXU4
Multiquip
15 kW
36 hp
→
Allmand Maxi-Power 15XR
Allmand · Towable Generator
15 kw
→
Generac MLG20IF4
Generac · Mobile Generator
19.0 kVA
1,832 lb (831 kg)
→
Doosan Portable Power G20WDO-3A-T4F
Doosan Portable Power · Mobile Generator
20.0 kVA
→
Chicago Pneumatic CPG 25 T4F
Chicago Pneumatic · Mobile Diesel Generator
→
Generac MDG25IF4
Generac · Mobile Generator
20.0 kVA
40 hp
2,771 lb (1,257 kg)
→
Multiquip DCA20SPXU4F
Multiquip · Equipment
29.9 kw
40 hp
1,797 lb (815 kg)
→
Multiquip DCA25SSIU4F
Multiquip · Equipment
30 kw
40 hp
→
Doosan Portable Power G25WDO-3A-T4F
Doosan Portable Power · Mobile Generator
25.0 kVA
→
Allmand Maxi-Power 25
Allmand · Mobile Generator
25.0 kVA
33 hp
2,780 lb (1,261 kg)
→
Wacker Neuson G25
Wacker Neuson · Mobile Generator
37 kw
1 hp
2,372 lb (1,076 kg)
→
Multiquip DCA-20SPXU2D
Multiquip
20 kW
34 hp
→
Multiquip DCA-25SSIU2
Multiquip
20 kW
→
Multiquip DCA-25SSIU3
Multiquip
20 kW
34 hp
→
Multiquip DCA-25USI
Multiquip
20 kW
34 hp
→
Multiquip DCA-25USI2
Multiquip
20 kW
34 hp
→
Multiquip DCA-25USI4CAN
Multiquip
20 kW
36 hp
2,227 lb (1,010 kg)
→
Multiquip DCA-25USIXF
Multiquip
20 kW
34 hp
→
Multiquip DCA20SPX
Multiquip
20 kW
34 hp
→
Multiquip DCA20SPXD
Multiquip
20 kW
1,433 lb (650 kg)
→
Multiquip DCA20SPXU2
Multiquip
20 kW
34 hp
→
Multiquip DCA20SPXU4CAN
Multiquip
20 kW
34 hp
1,440 lb (653 kg)
→
Multiquip DCA25SSI
Multiquip
20 kW
34 hp
→
Chicago Pneumatic CPG 45 T4F
Chicago Pneumatic · Mobile Diesel Generator
→
Generac MMG45IF4
Generac · Mobile Generator
38.0 kVA
59 hp
→
Multiquip DCA40SSKU4F2
Multiquip · Equipment
39 kw
52 hp
→
Doosan Portable Power G40WDO-3A-T4F
Doosan Portable Power · Mobile Generator
40.0 kVA
→
Multiquip DCA-40SSI
Multiquip
32 kW
→
Multiquip DCA40SSKU
Multiquip
32 kW
49 hp
→
Multiquip DCA40SSKU4F
Multiquip
32 kW
48 hp
→
Multiquip DCA45SSIU4F
Multiquip · Equipment
49 kw
66 hp
→
Allmand Maxi-Power 45
Allmand · Towable Generator
45.0 kVA
→
Multiquip DCA-36SPXU2
Multiquip
36 kW
67 hp
→
Multiquip DCA-45SSIU2
Multiquip
36 kW
→
Multiquip DCA-45SSIU3
Multiquip
36 kW
175 hp
→
Multiquip DCA-45SSKU
Multiquip
36 kW
73 hp
→
Multiquip DCA-45SSKU2
Multiquip
36 kW
73 hp
→
Multiquip DCA-45SSKU3
Multiquip
36 kW
→
Multiquip DCA-45SSKU4C
Multiquip
36 kW
73 hp
→
Multiquip DCA-45USI
Multiquip
36 kW
67 hp
→
Multiquip DCA-45USI2
Multiquip
36 kW
67 hp
→
Multiquip DCA-45USI4CAN
Multiquip
36 kW
67 hp
→
Multiquip DCA-45USIXF
Multiquip
36 kW
67 hp
→
Multiquip DCA36SPX
Multiquip
36 kW
67 hp
→
Page 1 of 2 Next →