Ir al contenido
Catálogo
← Fuel Tank
CAT CLASS: HQ-10902

1,000-2,000 gal Fuel Tank

The 1,000-2,000 gallon fuel tank class serves as the primary on-site fuel depot for multi-equipment operations, supporting generator banks and vehicle fleets through multi-day or week-long projects without resupply. This class occupies the second-largest rung on the fuel tank ladder, positioned between 500-1,000 gallon portable tanks and 2,000+ gallon stationary installations. Tanks in this range typically stand 7.6 to 13 feet tall and carry load capacities from 1,020 to 1,941 kilograms.

120
Modelos
16
Marcas
Fuel Tank

Cat classes

Elija una clase de tamaño — la capacidad y el alcance varían en la gama.

Especificaciones clave

EspecificaciónRango típicoQué significa
Capacity1,000–2,000 galVolume sufficient for extended fleet operations or large generator runtimes without daily refueling
Load capacity2,249–4,279 lb (1,020–1,941 kg)Combined weight of fuel and tank structure; determines trailer and foundation requirements
Max height7.6–13 ft (2.3–4.0 m)Vertical clearance needed for placement and pump access; affects transport and overhead restrictions

Cómo elegir

This size class is appropriate when supporting multiple generators simultaneously, fueling a mixed equipment fleet on extended projects, or eliminating weekly fuel deliveries on remote sites. Operations running a single large generator or small equipment group for short durations typically find the 500-1,000 gal Fuel Tank class more maneuverable and economical. Sites with permanent fuel infrastructure, continuous heavy equipment operation, or projects spanning months step up to the 2,000+ gal Fuel Tank class to reduce delivery frequency and achieve bulk pricing.

Lo que maneja este tamaño

  • Multi-week utility infrastructure projects with excavators, dozers, and generators operating concurrently
  • Agricultural operations fueling harvest equipment fleets during peak season
  • Emergency power installations supplying backup generators for critical facilities
  • Remote construction sites beyond economical reach of daily fuel delivery service
  • Event production supporting multiple generator banks for large-scale temporary installations
  • Mining exploration camps providing fuel for drilling rigs and support vehicles

Seguridad y operación

  • Secondary containment systems mandatory in most jurisdictions; double-wall construction or external berm required to capture 110% of tank volume
  • Grounding and bonding straps essential during dispensing operations to prevent static discharge ignition of fuel vapors
  • Spill kits, fire extinguishers, and visible signage required within immediate tank area per NFPA and OSHA guidelines
  • Overfill prevention devices and automatic shutoff nozzles standard on compliant installations to prevent environmental release

Transporte y logística

  • Delivered on tandem-axle or tri-axle trailers; larger units in this class may require commercial towing equipment rated for gross weights exceeding 15,000 lbs
  • Crane or forklift placement common for units at the upper end of the range; smaller 1,000-gallon models may allow skid-steer positioning
  • Transport permits and escort requirements vary by jurisdiction based on height and width; tallest configurations approaching 13 feet trigger overheight restrictions in many states

Alimentación

  • Most units in this class integrate electric pumps requiring 110V or 220V AC site power; diesel-powered pump options available for off-grid locations
  • Gravity-feed dispensing possible on elevated installations, though pump systems provide metered delivery and flow control
  • Solar panel kits paired with battery banks increasingly common for remote installations requiring pump operation without generator support

Preguntas frecuentes

How long does a 1,500-gallon tank supply a typical generator and equipment fleet?
Duration depends on load and fleet size. A 150 kW generator at 75% load consumes roughly 12 gallons per hour; combined with skid steer and excavator use, a 1,500-gallon tank typically supports 3-7 days of continuous operation before refill.
What foundation or pad is required for tanks in this size class?
Gravel or compacted aggregate pads at minimum 6 inches deep provide adequate support for most installations. Concrete pads or structural skids required on soft soils or when local codes mandate impermeable containment surfaces.
Do tanks in this class require permits or inspections?
Aboveground fuel storage exceeding 1,100 gallons typically triggers state and local permitting, fire marshal review, and periodic inspection requirements. Specific thresholds and compliance standards vary by jurisdiction and fuel type.

Comparar modelos populares

Buscar por especificación →

Normalizado a las mismas unidades. Un guion significa que el valor no fue publicado.

ModeloCapacidad de cargaAltura máx
Norwesco Horizontal Leg Tank 1025 gal (Premium) 1,025 gal11.6 ft (3.5 m)
Plastic-Mart Norwesco 1635 Gallon Horizontal Leg Tank (N-40400) 1,635 gal11.8 ft (3.6 m)
Transcube 50TCG 1,204 gal7.6 ft (2.3 m)
Western Global FuelCube FCP1800 1,754 gal13 ft (4.0 m)
Western Global TransCube Global 50TCG 1,154 gal7.7 ft (2.3 m)