Aller au contenu
Catalogue
← Generators

Portable Generator

A portable generator is an engine-driven power source built to be moved to the work—carried, wheeled, or loaded in a truck—and to feed tools, lighting, and equipment through onboard receptacles. The class centers on gasoline and small diesel units in the low-kilowatt range, the workhorse power source for crews operating away from grid service.

269
Modèles
5.0–560.0 kVA
Power output
15
Marques
Portable Generator

Cat classes

Choisissez une classe de taille — la capacité et la portée varient selon la gamme.

Fonctionnement

An engine drives an alternator at governed speed to hold 60 Hz output, with a voltage regulator maintaining output at nominal receptacle voltages. Loads plug directly into the panel: duplex receptacles for cords and tools, and twist-lock outlets for higher-current connections on larger units. Output is quoted as running (rated) watts and a higher surge figure for motor starting. Conventional units hold full governed speed whenever running; the class's larger wheeled members trade the refinement of inverter units for simpler construction and higher output per dollar.

Types et variantes

Recoil-start frame units
Open-frame gasoline generators at the small end, hand-carried or two-person lifted, serving hand tools and lighting.
Wheeled jobsite units
Mid-size frame generators with wheel kits and lifting bails, the standard crew power source in the 3–7 kW class.
Electric-start units
Larger portables with battery start and often twist-lock receptacle panels for feeding subpanels or trailers.
Small mobile diesel units
Compact diesel-powered generators bridging toward the towable class, favored where diesel fuel is already on site.

Spécifications clés

SpécificationPlage typiqueSignification
Power output5.0–560.0 kVARunning watts govern what operates simultaneously; the surge rating must cover the largest motor start.
Fuel capacity3.2–385.0 galTank size against load level sets refueling intervals during a shift.
Fuel consumption0.7–33.1 gal/hrConsumption scales with load; planning fuel for a shift means estimating average load, not nameplate output.
Engine power5.7–2220.0 hpEngine horsepower drives alternator output and determines the unit's continuous rating.

Comment l'industrie le dimensionne

The portable class is sized in kilowatts. Cataloged portable units group into bands: up to 3 kW, 3–7 kW, 7–12 kW, and 12+ kW. Selection sums the running watts of everything operating at once, adds the largest starting surge, and lands on the smallest unit that covers the total—oversizing wastes fuel and buys unnecessary weight.

Applications

  • Tool and cord power for crews on unpowered sites
  • Temporary lighting and small-equipment power
  • Backup power for homes, farms, and small commercial spaces
  • Powering pumps and heaters on service and maintenance work
  • Event and vendor power at the small end of the class
  • Supplementing site power at locations distant from the main generator

Sécurité et opération

  • Operate outdoors only, away from doors, windows, and vents—CPSC guidance is at least 20 feet from occupied structures; portable generators account for the majority of carbon monoxide deaths tied to consumer products.
  • Models with CO-sensing shutdown (built to UL 2201 or equivalent) add a critical layer of protection; the sensor must never be bypassed.
  • Never backfeed a building through a receptacle; connection to premises wiring requires a transfer switch or listed interlock.
  • Use GFCI protection for cord-connected tools, and elevate connections out of standing water.
  • Shut down and cool before refueling; gasoline spilled on a hot muffler is a fire cause on small generators.

Normes et certifications

UL · UL 2201
Standard for carbon-monoxide-mitigating portable generators.
NFPA · NFPA 70 (NEC), Articles 445 and 702
Generator installation and optional standby connection requirements, including transfer equipment.

Questions fréquentes

What is the difference between running watts and surge watts?
Running watts is the continuous output the generator sustains; surge watts is a short-duration reserve for motor starting. A unit must cover both the sum of running loads and the starting draw of the largest motor, which can be several times its running figure.
How does a portable generator differ from an inverter generator?
Conventional portables hold fixed governed engine speed and produce rougher power at lower cost per kW. Inverter units synthesize cleaner output electronically, run quieter, and throttle with load, but cost more at the same rating. Sensitive electronics favor inverter output.
Can a portable generator power a building during an outage?
Yes, within its rating, but only through a transfer switch or listed interlock installed at the panel. Backfeeding through an appliance receptacle is illegal and can kill utility line workers.
Why does the class data show units far larger than hand-portable sizes?
Catalog records group some large towable and stationary sets under the portable class, which stretches the recorded spec ranges well beyond the bands that define true hand-portable equipment.

Comparer les modèles populaires

Chercher par spécification →

Normalisé aux mêmes unités. Un tiret signifie que la valeur n'a pas été publiée.

ModèlePuissance de sortieCapacité de carburant
Allmand Maxi-Power 25 25.0 kVA52.0 gal
Multiquip DA7000SSA3 15.6 kVA6.6 gal
Multiquip DAC7000SSA3 6 kW28.0 gal
Multiquip DCA10SPXU4C 10 kW28.0 gal
Multiquip DCA15SPXU4F 14 kW28.0 gal
Wacker Neuson G25 25.0 kVA62.6 gal

Équipements connexes

Parcourir par fabricant

Sources

Chaque spécification est vérifiée par rapport aux données publiées par le fabricant, avec la source liée pour référence.

Tous les modèles

269 modèles · Page 5 sur 6 · Chaque spécification citée à la source

Kobalt KPG0100
Kobalt · Portable Generator
6.9 kVA
Multiquip DAC7000SSA3
Multiquip · Equipment
12 hp
6 kW
Multiquip DCA6SPX4F
Multiquip · Equipment
17 hp
6 kW
860 lb (390 kg)
Generac MLG8K
Generac · Mobile Generator
8.0 kVA
1,250 lb (567 kg)
Craftsman CMXGGFMP06009
Craftsman · Gas Portable Generator
9.4 kVA
Allmand Maxi-Power 8XR
Allmand · Towable Generator
10.0 kVA
Multiquip DCA10SPXU4C
Multiquip · Equipment
10 kW
1,107 lb (502 kg)
Multiquip DCA-10SPX3
Multiquip
10 kW
Multiquip DCA-10SPX4
Multiquip
24 hp
10 kW
Multiquip DCA10SPX
Multiquip
10 kW
Generac MLG15M
Generac · Mobile Generator
24 hp
13.0 kVA
1,843 lb (836 kg)
Multiquip DA7000SSA3
Multiquip · Equipment
12 hp
15.6 kVA
597 lb (271 kg)
Multiquip DCA15SPXU4F
Multiquip · Equipment
25 hp
14 kW
1,179 lb (535 kg)
Multiquip DCA-15SPX4
Multiquip
36 hp
15 kW
Multiquip DCA15SPX
Multiquip
36 hp
15 kW
Multiquip DCA15SPXU4
Multiquip
36 hp
15 kW
Allmand Maxi-Power 15XR
Allmand · Towable Generator
18.8 kVA
Generac MLG20IF4
Generac · Mobile Generator
19.0 kVA
1,832 lb (831 kg)
Doosan Portable Power G20WDO-3A-T4F
Doosan Portable Power · Mobile Generator
20.0 kVA
Chicago Pneumatic CPG 25 T4F
Chicago Pneumatic · Mobile Diesel Generator
20.0 kVA
Generac MDG25IF4
Generac · Mobile Generator
40 hp
20.0 kVA
2,771 lb (1,257 kg)
Multiquip DCA20SPXU4F
Multiquip · Equipment
40 hp
20 kW
1,797 lb (815 kg)
Multiquip DCA25SSIU4F
Multiquip · Equipment
40 hp
20 kW
Doosan Portable Power G25WDO-3A-T4F
Doosan Portable Power · Mobile Generator
25.0 kVA
Allmand Maxi-Power 25
Allmand · Mobile Generator
33 hp
25.0 kVA
2,780 lb (1,261 kg)
Wacker Neuson G25
Wacker Neuson · Mobile Generator
40 hp
25.0 kVA
2,372 lb (1,076 kg)
Multiquip DCA-20SPXU2D
Multiquip
34 hp
20 kW
Multiquip DCA-25SSIU2
Multiquip
20 kW
Multiquip DCA-25SSIU3
Multiquip
34 hp
20 kW
Multiquip DCA-25USI
Multiquip
34 hp
20 kW
Multiquip DCA-25USI2
Multiquip
34 hp
20 kW
Multiquip DCA-25USI4CAN
Multiquip
36 hp
20 kW
2,227 lb (1,010 kg)
Multiquip DCA-25USIXF
Multiquip
34 hp
20 kW
Multiquip DCA20SPX
Multiquip
34 hp
20 kW
Multiquip DCA20SPXD
Multiquip
20 kW
1,433 lb (650 kg)
Multiquip DCA20SPXU2
Multiquip
34 hp
20 kW
Multiquip DCA20SPXU4CAN
Multiquip
34 hp
20 kW
1,440 lb (653 kg)
Multiquip DCA25SSI
Multiquip
34 hp
20 kW
Chicago Pneumatic CPG 45 T4F
Chicago Pneumatic · Mobile Diesel Generator
36.0 kVA
Generac MMG45IF4
Generac · Mobile Generator
59 hp
38.0 kVA
Multiquip DCA40SSKU4F2
Multiquip · Equipment
48 hp
32 kW
Doosan Portable Power G40WDO-3A-T4F
Doosan Portable Power · Mobile Generator
40.0 kVA
Multiquip DCA-40SSI
Multiquip
32 kW
Multiquip DCA40SSKU
Multiquip
49 hp
32 kW
Multiquip DCA40SSKU4F
Multiquip
48 hp
32 kW
Multiquip DCA45SSIU4F
Multiquip · Equipment
66 hp
36 kW
Allmand Maxi-Power 45
Allmand · Towable Generator
45.0 kVA
Multiquip DCA-36SPXU2
Multiquip
67 hp
36 kW
← Préc. Page 5 sur 6 Suiv. →