Aller au contenu
Catalogue
← Scaffolding

Rolling Tower (Baker) Scaffold

A rolling tower scaffold, commonly called a baker scaffold, is a mobile aluminum or steel work platform supported by a rectangular frame with locking casters at the base. These scaffolds provide elevated access for interior construction, maintenance, and finishing tasks where portability and repositioning are required. The modular frame design allows vertical stacking to reach various working heights while maintaining mobility.

24
Modèles
3.6–27 ft (1.1–8.2 m)
Maximum Height
5
Marques
Rolling Tower (Baker) Scaffold

Cat classes

Choisissez une classe de taille — la capacité et la portée varient selon la gamme.

Fonctionnement

The scaffold consists of one or more interlocking frame sections that stack vertically and lock together with pins or clip mechanisms. Each section typically includes side frames, cross braces, and a platform deck. Locking casters at the base allow the unit to be rolled into position, then secured in place by engaging wheel locks or brakes. Guardrails attach to the upper section to provide fall protection at the working level. For heights beyond two sections, outriggers extend from the base to increase stability and meet tip-over safety requirements. Workers access the platform via integrated ladder rungs on the end frames or attached ladder assemblies. The narrow profile of most units permits passage through standard doorways and movement within confined interior spaces.

Types et variantes

Single-Section Baker Scaffold
Non-stackable base unit, typically 3–6 ft platform height, designed for low-level interior work and doorway passage.
Multi-Section Stackable Tower
Modular frames that interlock vertically, reaching 12–27 ft, with guardrails and outriggers for extended height applications.
Narrow Frame Scaffold
Compact width design (typically 29–30 in.) specifically engineered to fit through residential and commercial doorways.
Wide-Base Utility Scaffold
Broader footprint for increased stability in open areas, often with larger work platforms for material handling.
Fold-Up Rolling Tower
Hinged frame sections that collapse for transport and storage, commonly used in facilities maintenance operations.

Spécifications clés

SpécificationPlage typiqueSignification
Maximum Height3.6–27 ft (1.1–8.2 m)Maximum platform height achievable with available frame sections; taller configurations require outriggers.
Platform Size29 × 72 in. (narrow frame)Work surface dimensions; narrow frames pass through 36 in. doorways, wider models offer more workspace.
Load Capacity500–1,000 lbs (227–454 kg)Combined weight rating for workers, tools, and materials on the platform deck.
Frame MaterialAluminum or steelAluminum units offer lighter weight for frequent repositioning; steel provides durability for heavy-duty use.
Caster Size5–8 in. diameterWheel diameter affects rolling ease and floor protection; larger casters navigate uneven surfaces more effectively.

Comment l'industrie le dimensionne

The industry sizes rolling tower scaffolds by maximum platform height in feet, corresponding to the number of frame sections stacked. Single-section units (3–6 ft) serve standard room heights and pass through doorways for interior access. Two-section configurations (6–12 ft) address commercial ceiling heights and elevated mechanical work. Three-section and taller towers (12+ ft) require outrigger stabilization and are specified for tall interior spaces, atriums, and theatrical rigging. Width classification distinguishes narrow-frame models (approximately 29 in.) designed for doorway passage from wider utility models prioritizing platform area.

Applications

  • Interior drywall installation, taping, and finishing in residential and commercial construction
  • Ceiling tile installation, HVAC ductwork, and electrical fixture mounting in commercial spaces
  • Interior painting and coating application on walls, ceilings, and high trim work
  • Maintenance access to lighting, sprinkler systems, and building equipment in occupied facilities
  • Theatrical rigging, lighting adjustments, and event setup in auditoriums and convention spaces
  • Warehouse and retail fixture installation, signage mounting, and inventory access

Sécurité et opération

  • Engage all wheel locks before ascending; ensure casters are on firm, level surfaces free of debris and obstructions.
  • Never move the scaffold while workers or materials are on the platform; all personnel must descend before repositioning.
  • Install outriggers and comply with height-to-base ratio requirements (typically 4:1) when stacking sections beyond manufacturer specifications.
  • Inspect frame connections, locking pins, and platform decks before each use; verify guardrails are properly installed at working height.
  • Maintain three-point contact when climbing; do not overload the platform or lean beyond the guardrail perimeter.

Normes et certifications

ANSI · A92.5
American National Standard for mobile scaffolding towers, covering design, construction, and safe use requirements.
OSHA · 29 CFR 1926.452
Federal regulations for mobile scaffolds including platform construction, guardrails, and stability criteria.
ANSI · A10.8
Safety requirements for scaffolding used in construction, demolition, and maintenance operations.
CSA · S269.2
Canadian standard for access scaffolding, applicable to rolling towers used in Canadian jurisdictions.

Questions fréquentes

What distinguishes a baker scaffold from other mobile scaffold types?
Baker scaffolds feature a narrow rectangular frame design with end-frame ladder access and integrated casters, specifically engineered to fit through standard doorways. The term originated from the Perry Company's Baker™ model, which became the generic industry designation for this configuration.
How many frame sections can be safely stacked without outriggers?
Most manufacturers limit stacking to two sections (approximately 10–12 ft height) without outriggers, maintaining a 4:1 height-to-minimum-base-width ratio. Three or more sections require outrigger stabilization to prevent tip-over, with specific requirements varying by manufacturer and frame width.
What floor conditions are unsuitable for rolling tower scaffolds?
Rolling towers should not be used on soft, uneven, or sloped surfaces, loose materials, or floors with significant cracks or gaps. Outdoor use on asphalt or soil typically requires plywood base plates or outrigger pads to distribute load and prevent sinking or tipping.
Are rolling scaffolds permitted for exterior building work?
While structurally capable, most rolling towers are classified for interior use due to their lightweight construction and mobility features. Exterior applications require wind bracing, tie-offs, and stability measures typically found in heavier-duty frame or system scaffolding designed for outdoor exposure.

Comparer les modèles populaires

Chercher par spécification →

Normalisé aux mêmes unités. Un tiret signifie que la valeur n'a pas été publiée.

ModèleHauteur maxCapacité de charge
Bil-Jax Pro-Jax Utility Scaffold 10.5 ft (3.2 m)1,001 lb (454 kg)
Metaltech 12ft Complete Fiberglass Baker Scaffold Tower Set 12 ft (3.7 m)642 lb (291 kg)
Metaltech 18ft Complete Fiberglass Baker Scaffold Tower Set 18 ft (5.5 m)560 lb (254 kg)

Équipements connexes

Parcourir par fabricant

Sources

Chaque spécification est vérifiée par rapport aux données publiées par le fabricant, avec la source liée pour référence.

Tous les modèles

24 modèles · Chaque spécification citée à la source

Dewalt DWST11031
Dewalt · Saw Horses
2,500 lb (1,134 kg)
Metaltech Complete Motorized Fiberglass 6ft Baker Scaffold Kit
Metaltech · Portable Scaffold Kit
500 lb (227 kg)
Bil-Jax Rolling Tower 10x10RT
Bil-Jax · Scaffold - Rolling Tower
Bil-Jax Rolling Tower 7x25RT
Bil-Jax · Scaffold - Rolling Tower
Cotterman 1001G
Cotterman · Baker Scaffold
Cotterman 1001N
Cotterman · Baker Scaffold
Cotterman 1002R
Cotterman · Baker Scaffold
Cotterman 1003R
Cotterman · Baker Scaffold
Cotterman 1004R
Cotterman · Baker Scaffold
Cotterman 1005R
Cotterman · Baker Scaffold
Perry 4100 Classic — 10' Long 4' High Complete Scaffold (no casters)
Perry · Baker's Style Rolling Scaffold
3.6 ft (1.1 m)
Perry 440 Classic — 4' Long 4' High Complete Scaffold (no casters)
Perry · Baker's Style Rolling Scaffold
3.6 ft (1.1 m)
Perry 460 Classic — 6' Long 4' High Complete Scaffold (no casters)
Perry · Baker's Style Rolling Scaffold
3.6 ft (1.1 m)
Perry 480 Classic — 8' Long 4' High Complete Scaffold (no casters)
Perry · Baker's Style Rolling Scaffold
3.6 ft (1.1 m)
Perry 6100 Classic — 10' Long 6' High Complete Scaffold (no casters)
Perry · Baker's Style Rolling Scaffold
6 ft (1.8 m)
Perry 640 Classic — 4' Long 6' High Complete Scaffold (no casters)
Perry · Baker's Style Rolling Scaffold
6 ft (1.8 m)
Perry 660 Classic — 6' Long 6' High Complete Scaffold (no casters)
Perry · Baker's Style Rolling Scaffold
6 ft (1.8 m)
Perry 680 Classic — 8' Long 6' High Complete Scaffold (no casters)
Perry · Baker's Style Rolling Scaffold
6 ft (1.8 m)
Bil-Jax Pro-Jax Utility Scaffold
Bil-Jax Pro-Jax Utility Scaffold
Bil-Jax · Scaffold - Utility Scaffold
10.5 ft (3.2 m)
1,001 lb (454 kg)
Metaltech 12ft Complete Fiberglass Baker Scaffold Tower Set
Metaltech · Portable Scaffold Tower
12 ft (3.7 m)
642 lb (291 kg)
Bil-Jax Rolling Tower 7x10RT
Bil-Jax Rolling Tower 7x10RT
Bil-Jax · Scaffold - Rolling Tower
17 ft (5.2 m)
Metaltech 18ft Complete Fiberglass Baker Scaffold Tower Set
Metaltech · Portable Scaffold Tower
18 ft (5.5 m)
560 lb (254 kg)
Bil-Jax Rolling Tower 7x15RT
Bil-Jax Rolling Tower 7x15RT
Bil-Jax · Scaffold - Rolling Tower
22 ft (6.7 m)
Bil-Jax Rolling Tower 7x20RT
Bil-Jax Rolling Tower 7x20RT
Bil-Jax · Scaffold - Rolling Tower
27 ft (8.2 m)