Skip to content
Catalog
← Dewatering Pumps

High-Head Pump

A high-head pump is a dewatering pump designed to move water against significant vertical elevation or pressure head, typically measured in feet of lift. These pumps deliver the pressure necessary to raise water from deep excavations, pump vertically up hillsides or building risers, or overcome long horizontal distances with friction losses. High-head pumps are distinguished from standard dewatering pumps by their ability to generate pressures sufficient for lifts ranging from tens to hundreds of feet.

67
Models
0–200 ft, 200–400 ft, 400+ ft
Total Head (ft)
12
Brands
High-Head Pump

Cat classes

Pick a size class — capacity and reach differ across the range.

How it works

High-head pumps achieve their lifting capability through multistage impeller configurations or high-speed single-stage designs that convert mechanical energy into fluid pressure. Powered by engines or electric motors ranging from 5.5 to 1000 hp, these pumps force water through progressively narrowing volutes or multiple impeller stages, each adding incremental pressure to overcome gravitational head and system friction. Discharge pressures are governed by the total dynamic head (TDH) requirement, which accounts for vertical lift, friction losses, and any residual discharge pressure needed at the outlet. The pump curve defines the relationship between flow rate and achievable head: as head increases, flow rate decreases along the performance envelope. Selection of pump models and operating points is based on the specific combination of required lift height and desired flow volume, ensuring the pump operates within its efficient performance range without cavitation or overload.

Types & variants

Multistage Centrifugal
Multiple impeller stages in series, each adding pressure; efficient for high heads with moderate flow rates.
Submersible High-Head
Submerged motor and pump assembly for in-sump operation; eliminates priming concerns and reduces noise.
Self-Priming High-Pressure
Surface-mounted units with priming chambers; suited for intermittent or varying water levels where submersion is impractical.
Diesel-Driven Booster
Engine-powered units for remote sites without electrical infrastructure; higher portability and fuel-based runtime.
Electric High-Lift
Grid or generator-powered motors for continuous operation; quieter and cleaner exhaust than engine-driven alternatives.

Key specifications

SpecificationTypical rangeWhat it means
Total Head (ft)0–200 ft, 200–400 ft, 400+ ftVertical lift plus friction losses; primary sizing criterion for high-head pump selection.
Flow Rate32–8,600 gpmVolume of water delivered per minute; inversely related to head along the pump curve.
Engine/Motor Power5.5–1,000 hpMechanical power input; higher power enables greater flow and head combinations.
Discharge Size2–12 in (5.1–30.5 cm)Outlet connection diameter; influences flow capacity and piping compatibility.

How the industry sizes it

High-head pumps are sized primarily by the total dynamic head (TDH) required, expressed in feet of lift, which represents the vertical elevation plus friction losses and system pressure needs. The industry commonly segments applications into bands: 0–200 ft lifts water out of a deep excavation or up a few storeys; 200–400 ft pumps up a hillside, a high-rise riser, or over a levee; and 400 ft and above for mine, quarry, and tall-building lifts. Flow rate requirements (gpm) and discharge size (inches) further refine selection, with pump curves used to match the operating point to the duty cycle. Engine or motor power (hp) scales with the combined demand of head and flow.

Applications

  • Deep excavation dewatering in urban construction and tunnel projects
  • Vertical water transport up hillsides, levees, or embankments
  • High-rise building water supply and fire suppression riser boosting
  • Mine and quarry dewatering from depths exceeding 400 feet
  • Long-distance horizontal pumping where friction head approaches vertical lift equivalents
  • Emergency flood control and bypass pumping over barriers

Safety & operation

  • Verify system pressure ratings and piping integrity to prevent rupture or blowout under high-head conditions
  • Monitor for cavitation and operate within the pump's recommended performance envelope to avoid mechanical damage
  • Provide adequate ventilation for engine-driven units and ensure exhaust is directed away from occupied areas
  • Install and maintain discharge check valves and pressure relief devices to manage backflow and overpressure events
  • Inspect electrical connections, grounding, and GFCI protection on electric models, especially in wet environments

Standards & certifications

OSHA · 29 CFR 1926.302
Guarding and safe operation of powered pumping equipment on construction sites.
ANSI/HI · ANSI/HI 9.6.1–9.6.9
Hydraulic Institute standards for centrifugal and vertical pump design, testing, and performance.
EPA · Tier 4
Emissions standards for diesel engines powering high-head pumps in non-road applications.

Frequently asked

What is the difference between a high-head pump and a standard dewatering pump?
High-head pumps are engineered to generate significantly higher discharge pressures to overcome large vertical lifts or long-distance friction losses, whereas standard dewatering pumps prioritize flow volume at lower heads, typically under 100 feet.
How is total dynamic head (TDH) calculated?
TDH is the sum of static vertical lift, friction losses in piping and fittings, and any required discharge pressure at the outlet. Pump selection must meet or exceed the TDH at the desired flow rate according to the pump curve.
Can a high-head pump operate at lower heads without damage?
Operating far to the right of the pump curve (low head, high flow) can lead to overload of the motor or engine, excessive wear, and reduced efficiency. Throttling the discharge valve or selecting a model suited to the actual duty point is recommended.
What causes cavitation in high-head pumps?
Cavitation occurs when suction-side pressure drops below the vapor pressure of water, forming and collapsing bubbles that damage impellers. Ensuring adequate net positive suction head (NPSH) available, proper suction piping, and avoiding excessive lift on the suction side prevent cavitation.

Compare popular models

Find by spec →

Normalised to the same units. A dash means the figure was not published.

ModelFlow rateMax headEngine power
BJM Pumps KHD110 179 gpm226 ft (68.9 m)-
Echo FP-2126 126 gpm-6 hp
Hydromatic SPD50H/SPD100H 110 gpm50 ft (15.2 m)-
NLB Corp 125 Series Electric Unit (Model 125) 32 gpm-125 hp
NLB Corp 225 Series Electric Unit (Model 225) 44 gpm-250 hp
NLB Corp 325 Series Electric Unit (Model 355E) 74 gpm-350 hp

Related equipment

Browse by manufacturer

Sources

Every specification is verified against the manufacturer's published data, with the source linked for reference.

All models

67 models · Page 1 of 2 · Every spec cited to source

Hydromatic HE Series (HE8/HE12/HE20/HE25/HE30/HE35/HE50)
Hydromatic HE Series (HE8/HE12/HE20/HE25/HE30/HE35/HE50)
Hydromatic · Submersible High-Head Stainless Steel Effluent Pump
72 gpm
Echo FP-2126
Echo · Fire Pump
126 gpm
6 hp
Gorman-Rupp Tankleenor Unit 608
Gorman-Rupp · Petroleum Tank Cleaning System
NLB Corp 175 Series Diesel Unit
NLB Corp · Diesel High-Pressure Waterjet Unit
29 gpm
188 hp
BJM Pumps KHD750
BJM Pumps · Submersible High-Head Slurry Pump
870 gpm
Pentair Myers MPB Series High Pressure Booster Pumps
Pentair Myers MPB Series High Pressure Booster Pumps
Pentair Myers · Booster Pump
7 gpm
Vacall AllJet
Vacall AllJet
Vacall · Truck-Mounted Jetter
87 gpm
Griffin 10x10-Patterson DMD 3600
Griffin · High-Pressure Fill Pump
2,400 gpm
Griffin 4x2-IR
Griffin · High-Pressure Fill Pump
100 gpm
Griffin 4x3-Patterson DMD 900
Griffin · High-Pressure Fill Pump
200 gpm
Griffin 5TUT-1600
Griffin · High-Pressure Fill Pump
1,050 gpm
Griffin 5x3-Patterson 950
Griffin · High-Pressure Fill Pump
625 gpm
Griffin 6x6-Patterson DMD 2000
Griffin · High-Pressure Fill Pump
1,350 gpm
Griffin Dewatering 4x2-IR
Griffin Dewatering · High Pressure Fill Pump
100 gpm
Griffin Dewatering 4x3-Patterson DMD 900
Griffin Dewatering · High Pressure Fill Pump
200 gpm
Griffin Dewatering 5x3-Patterson 950
Griffin Dewatering · High Pressure Fill Pump
625 gpm
NLB Corp 225 Series Diesel Unit (Model 355D)
NLB Corp · Diesel High-Pressure Waterjet Unit
63 gpm
350 hp
NLB Corp 325 Series Diesel Unit (Model 455D)
NLB Corp · Diesel High-Pressure Waterjet Unit (Quintuplex)
79 gpm
450 hp
NLB Corp 325 Series Electric Unit (Model 355E)
NLB Corp · Electric High-Pressure Waterjet Unit (Quintuplex)
74 gpm
350 hp
Griffin 10x8-Cornell 8NHTA
Griffin · High-Pressure Centrifugal Pump
5,050 gpm
Griffin 10x8-Cornell 8NHTH
Griffin · High-Head Centrifugal Pump
8,600 gpm
Griffin 10x8-Pioneer VP108S17
Griffin · High-Pressure Centrifugal Pump
6,900 gpm
Griffin 12x8-Cornell 8NHG19
Griffin · High-Head Centrifugal Pump
7,000 gpm
Griffin 12x8-Pioneer PP128S22
Griffin · High-Head Centrifugal Pump
12,000 gpm
Griffin 4x3-Cornell 4319MX
Griffin · High-Pressure Centrifugal Pump
860 gpm
Griffin 4x4-Cornell 4414T
Griffin · High-Pressure Centrifugal Pump
1,690 gpm
Griffin 6x4-Cornell 4622MX
Griffin · High-Head Centrifugal Pump
1,680 gpm
Griffin 6x4-Pioneer VP64S17
Griffin · High-Pressure Centrifugal Pump
2,550 gpm
Griffin 8x6-Cornell 6822MX
Griffin · High-Head Centrifugal Pump
4,250 gpm
Griffin 8x6-Cornell 6HH
Griffin · High-Pressure Centrifugal Pump
4,100 gpm
Griffin 8x6-Pioneer PP86C21
Griffin · High-Head Centrifugal Pump
4,000 gpm
Griffin 8x6-Pioneer VP86S17
Griffin · High-Pressure Centrifugal Pump
3,990 gpm
Griffin Dewatering 10x10-Patterson DMD 3600
Griffin Dewatering · High Pressure Fill Pump
2,400 gpm
Griffin Dewatering 6x6-Patterson DMD 2000
Griffin Dewatering · High Pressure Fill Pump
1,350 gpm
Hydro-Force TCBS Sprayer 3-Gallon
Hydro-Force · Pump-Up Sprayer
NLB Corp 1005 Series Diesel Unit (Model 1005D)
NLB Corp · Diesel High-Pressure Waterjet Unit
333 gpm
1,000 hp
NLB Corp 125 Series Electric Unit (Model 125)
NLB Corp · Electric High-Pressure Waterjet Unit
32 gpm
125 hp
NLB Corp 225 Series Electric Unit (Model 225)
NLB Corp · Electric High-Pressure Waterjet Unit
44 gpm
250 hp
NLB Corp 605 Series Diesel Unit (Model 605D)
NLB Corp · Diesel High-Pressure Waterjet Unit
200 gpm
600 hp
NLB Corp 605 Series Electric Unit (Model 500E)
NLB Corp · Electric High-Pressure Waterjet Unit
200 gpm
500 hp
Griffin Dewatering 10x8-Cornell 8NHTA Vac-Assist/Trailer
Griffin Dewatering · High Pressure Pump
5,050 gpm
Griffin Dewatering 10x8-Cornell 8NHTH Vac-Assist
Griffin Dewatering · High Head Pressure Pump
8,600 gpm
Griffin Dewatering 10x8-Pioneer VP108S17 Vac-Assist/Trailer
Griffin Dewatering · High Pressure Pump
6,900 gpm
Griffin Dewatering 12x8-Cornell 8NHG19 Vac-Assist
Griffin Dewatering · High Head Pressure Pump
7,000 gpm
Griffin Dewatering 12x8-Pioneer PP128S22 Vac-Assist
Griffin Dewatering · High Head Pressure Pump
12,000 gpm
Griffin Dewatering 4x3-Cornell 4319MX Vac-Assist/Trailer
Griffin Dewatering · High Pressure Pump
860 gpm
Griffin Dewatering 4x4-Cornell 4414T Vac-Assist/Trailer
Griffin Dewatering · High Pressure Pump
1,690 gpm
Griffin Dewatering 6x4-Cornell 4622MX Vac-Assist
Griffin Dewatering · High Head Pressure Pump
1,680 gpm
Page 1 of 2 Next →